2016
DOI: 10.1515/cclm-2015-1094
|View full text |Cite
|
Sign up to set email alerts
|

Prospective validation of an automated chemiluminescence-based assay of renin and aldosterone for the work-up of arterial hypertension

Abstract: Background: The availability of simple and accurate assays of plasma active renin (DRC) and aldosterone con centration (PAC) can improve the detection of secondary forms of arterial hypertension. Thus, we investigated the performance of an automated chemiluminescent assay for DRC and PAC in referred hypertensive patients. Methods: We prospectively recruited 260 consecu tive hypertensive patients referred to an ESH Center for Hypertension. After exclusion of six protocol violations, 254 patients were analyzed: … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
39
1
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 70 publications
(43 citation statements)
references
References 31 publications
1
39
1
2
Order By: Relevance
“…Among the 3 major studies on recently developed enzyme assays of ARC. 7,12,13 Manolopoulou et al reported that their iSYS ARC assay was traceable to World Health Organization international standard renin (code 68/356) with its conversion factor of 1.67 (unit conversion from pg/mL to μIU/mL, meaning one unit of standard renin was measured as 600 ng using iSYS ARC assay). We used the same World Health Organization international standard of renin and determined that one unit of the renin was measured as 591 ng using Accuraseed ARC assay with conversion factor of 1.692 (unit conversion from pg/mL to μIU/mL; as shown in Methods and Results in the online-only Data Supplement).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Among the 3 major studies on recently developed enzyme assays of ARC. 7,12,13 Manolopoulou et al reported that their iSYS ARC assay was traceable to World Health Organization international standard renin (code 68/356) with its conversion factor of 1.67 (unit conversion from pg/mL to μIU/mL, meaning one unit of standard renin was measured as 600 ng using iSYS ARC assay). We used the same World Health Organization international standard of renin and determined that one unit of the renin was measured as 591 ng using Accuraseed ARC assay with conversion factor of 1.692 (unit conversion from pg/mL to μIU/mL; as shown in Methods and Results in the online-only Data Supplement).…”
Section: Discussionmentioning
confidence: 99%
“…9,10 On the contrary, measurement of plasma renin concentrations without using radioactive materials has been recently reported. 7,8,1113 However, currently available assays for renin concentration have relatively poor sensitivities when compared with assays for plasma renin activity (PRA). It is true that the sensitivities of PRA assay have been improved by prolonging incubation time to produce more angiotensin I, making it possible to achieve sensitivity of <1.0 ng/mL per hour, 14 while producing a dilemma as to sensitivity versus rapidity.…”
mentioning
confidence: 99%
“…Measurements were performed on a LIAISON XL Analyzer. [7] Inter-assay and intra-assay coefficients of variability (CV) for renin determination are between 2.1–2.4% and 6.8–7.3%, respectively. Inter-assay CV and intra-assay CV for aldosterone determination are between 1.8–3.5% and 5.6–9.5% respectively.…”
Section: Methodsmentioning
confidence: 99%
“…[2–4] More recently an elevation in aldosterone levels was also reported in hypertensive patients with atrial fibrillation (AF). [57] However, whether aldosterone is elevated in normotensive patients with AF or other cardiac conditions is unknown. Furthermore, it is unclear whether alterations of the aldosterone-renin ratio (ARR) exist in unselected cardiac patients undergoing cardiac catheterization.…”
Section: Introductionmentioning
confidence: 99%
“…These hormones can nowadays be measured with unprecedented accuracy in many laboratories around the world and will be even more widely available thanks to the development of accurate chemiluminescent automated simultaneous assays [12].…”
Section: Aldosterone Renin Ratio (Arr)-appmentioning
confidence: 99%