2002
DOI: 10.1136/ard.61.10.895
|View full text |Cite
|
Sign up to set email alerts
|

Prospective two year follow up study comparing novel and conventional imaging procedures in patients with arthritic finger joints

Abstract: Objective: To carry out a prospective two year follow up study comparing conventional radiography, three-phase bone scintigraphy, ultrasonography (US), and three dimensional (3D) magnetic resonance imaging (MRI) with precontrast and dynamic postcontrast examination in detecting early arthritis. The aim of the follow up study was to monitor the course of erosions during treatment with disease modifying antirheumatic drugs by different modalities and to determine whether the radiographically occult changes like … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
133
1
15

Year Published

2009
2009
2013
2013

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 250 publications
(153 citation statements)
references
References 40 publications
4
133
1
15
Order By: Relevance
“…It has been increasingly used in rheumatologic practice and research in the last decade, especially in small joints of the hands and fingers (1)(2)(3). By contrast, large joints have not been extensively studied, and knee involvement has only been incorporated in a 12-joint US score proposed by Naredo and colleagues (3).…”
Section: Introductionmentioning
confidence: 99%
“…It has been increasingly used in rheumatologic practice and research in the last decade, especially in small joints of the hands and fingers (1)(2)(3). By contrast, large joints have not been extensively studied, and knee involvement has only been incorporated in a 12-joint US score proposed by Naredo and colleagues (3).…”
Section: Introductionmentioning
confidence: 99%
“…SF is visualized as an anechoic area within the joint capsule, while SH is visualized as hypoechoic material within and involving the joint capsule. Ultrasound has been shown to be superior to clinical examination in detecting and evaluating these 2 crucial components in a range of studies performed on various joints 3,4 . Both SF and SH are evaluated primarily on gray-scale (GS) ultrasound, while Color Doppler (CD) and Power Doppler (PD) are utilized to demonstrate activity related to SH.…”
mentioning
confidence: 99%
“…Although AS affects primarily the axial skeleton, peripheral joints and extra-articular structures may also be involved. The main use of US in AS and SpA is the detection of peripheral joint pathologies, including synovial effusion, hypertrophy, enthesopathy, and increased Doppler signals at sites of entheses (16,17).…”
Section: Ankylosing Spondylitismentioning
confidence: 99%