2011
DOI: 10.1002/mrm.23295
|View full text |Cite
|
Sign up to set email alerts
|

Prospective self‐gating for swallowing motion: A feasibility study in carotid artery wall MRI using three‐dimensional variable‐flip‐angle turbo spin‐echo

Abstract: Three-dimensional (3D) black-blood MRI is a promising noninvasive imaging technique for the assessment of atherosclerotic carotid artery disease. However, this technique is inherently susceptible to motion. In particular, swallowing can result in considerable wall motion at the carotid bifurcations, which may induce drastic image degradation or substantial overestimation of wall thickness. Self-gating (SG) techniques have previously been shown to be capable of resolving and compensating for cardiac or respirat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 14 publications
(24 citation statements)
references
References 25 publications
1
23
0
Order By: Relevance
“…One way to mitigate pulsatile motion is the use of ECG triggering, which should not increase scan time because the TR in the current protocol is similar to a typical RR interval. Navigator (27) or self-gating (28) methods may be adopted in the future. Third, we only designed a T1w protocol in order to reduce the overall exam duration.…”
Section: Discussionmentioning
confidence: 99%
“…One way to mitigate pulsatile motion is the use of ECG triggering, which should not increase scan time because the TR in the current protocol is similar to a typical RR interval. Navigator (27) or self-gating (28) methods may be adopted in the future. Third, we only designed a T1w protocol in order to reduce the overall exam duration.…”
Section: Discussionmentioning
confidence: 99%
“…Abrupt movement of the subject, such as swallowing, is often inevitable during any scan that spans several minutes . Unaddressed abrupt bulk motion leads to blurring and other motion artifacts.…”
Section: Methodsmentioning
confidence: 99%
“…Abrupt movement of the subject, such as swallowing, is often inevitable during any scan that spans several minutes. 38 Unaddressed abrupt bulk motion leads to blurring and other motion artifacts. Because the carotid vessel wall is thin, it is especially sensitive to motion artifacts that worsen the partial volume effect, leading to incomplete vessel wall visualization and errors in quantification.…”
Section: Abrupt Motion Removalmentioning
confidence: 99%
“…Recently, a three-dimensional (3D) CMR vessel wall imaging (VWI) technique based on 3D T1 weighted (T1w) Sampling Perfection with Application-optimized Contrast using different flip-angle Evolutions (SPACE) has become technically feasible and gained increasing attention for the diagnosis of atherosclerosis [22][23][24][25][26]. This technique is advantageous over conventional two-dimensional techniques, as it has sufficient BB effects, large spatial coverage, high isotropic resolution and signal-to-noise ratio (SNR), excellent scan efficiency, and remarkable cerebrospinal fluid (CSF) signal attenuation [23,24,27].…”
Section: Introductionmentioning
confidence: 99%