2022
DOI: 10.1007/s00264-022-05501-2
|View full text |Cite
|
Sign up to set email alerts
|

Prospective randomized controlled trial on the accuracy of prosthesis positioning in total hip arthroplasty assisted by a newly designed whole-process robotic arm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…The AML or Osteoloc stem was utilized in two [ 9 , 23 ] and the S-ROM in one study [ 11 ], while two other studies did not specify the stem type used [ 24 , 28 ]. The posterolateral approach was the most common ( n = 5) [ 9 , 23 , 25 27 ], followed by the anterolateral approach ( n = 1) [ 11 ], and modified Hardinge approach ( n = 1) [ 28 ], with one study not detailing the approach employed [ 24 ]. The Harris Hip Score (HHS) was the most common PROMs reported in six studies [ 9 , 11 , 23 , 24 , 26 , 28 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The AML or Osteoloc stem was utilized in two [ 9 , 23 ] and the S-ROM in one study [ 11 ], while two other studies did not specify the stem type used [ 24 , 28 ]. The posterolateral approach was the most common ( n = 5) [ 9 , 23 , 25 27 ], followed by the anterolateral approach ( n = 1) [ 11 ], and modified Hardinge approach ( n = 1) [ 28 ], with one study not detailing the approach employed [ 24 ]. The Harris Hip Score (HHS) was the most common PROMs reported in six studies [ 9 , 11 , 23 , 24 , 26 , 28 ].…”
Section: Resultsmentioning
confidence: 99%
“…For LLD, the results from four studies [ 11 , 24 , 25 , 28 ] recruiting 346 hips were combined with considerable heterogeneity ( I 2 = 86%). LLD for RATHA was on average 4 mm less than that of the COTHA group (95%CI − 7.08 to − 1.0 mm, low certainty) (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Modern software allows precise component planning and enables the surgeon to place the component to a predetermined reaming depth. [12][13][14] This planning software can determine if lateral cup placement will cause the acetabular component to be uncovered and can help the surgeon determine final cup placement. The software also allows the surgeons to place the smallest cup that is likely to gain a good press fit with an ability to upsize if a larger component is needed.…”
Section: Discussionmentioning
confidence: 99%
“…This directly impacts prosthesis survival. The use of full-process robotics can enhance the precision of cup and stem placement [12] , potentially prolonging prosthesis longevity in DDH patients.…”
Section: Introductionmentioning
confidence: 99%