Prospective Randomized Comparison of Standard Hand Pump Infuser Irrigation vs an Automated Irrigation Pump During Percutaneous Nephrolithotomy and Ureteroscopy: Assessment of Operating Room Efficiency and Surgeon Satisfaction

Abstract: Introduction:The objective of this study was to determine if use of an automated irrigation pump (AIP) during ureteroscopy (URS) and percutaneous nephrolithotomy (PCNL) affects circulating nurse labor, irrigationrelated issues, and surgeon and nurse satisfaction when compared to manual hand pump (HP) irrigation. Methods: Eighty consecutive adult patients undergoing unilateral URS or PCNL were prospectively randomized to irrigation with the HP or AIP. Preoperative pump setup time, intraoperative pump maintenanc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 21 publications
0
4
0
1
Order By: Relevance
“…showing that automated systems are more popular compared to hand pump due to ease of use and less reliance on operating room staff. [13] Some studies support that judicious use of hand irrigation can maintain low pressures, but pressures can reach dangerous levels if a careful touch is not maintained. [7] The normal physiologic intrarenal pressure is roughly 10 mmHg.…”
Section: Discussionmentioning
confidence: 99%
“…showing that automated systems are more popular compared to hand pump due to ease of use and less reliance on operating room staff. [13] Some studies support that judicious use of hand irrigation can maintain low pressures, but pressures can reach dangerous levels if a careful touch is not maintained. [7] The normal physiologic intrarenal pressure is roughly 10 mmHg.…”
Section: Discussionmentioning
confidence: 99%
“…A randomized controlled trial of 51 patients in the United States undergoing percutaneous nephrolithotomy and URS found significantly less irrigation concerns, decreased pump time, and increased nurse satisfaction when using automated irrigation pumps when compared with manual pumps. 11 While there are no data on the most commonly chosen irrigation pressures in North America, a recent bench study of automated irrigation systems conducted by urologists in the United States were done at pressure settings with a maximum of 300 mmHg to mimic clinical practice. 12 In another US bench study where a setting of 200 mmHg with the pressurized saline bag was used, it was noted that a pressure in excess of 300 mmHg may occur in the operating room.…”
Section: Discussionmentioning
confidence: 99%
“…A randomized controlled trial of 51 patients in the United States undergoing percutaneous nephrolithotomy and URS found significantly less irrigation concerns, decreased pump time, and increased nurse satisfaction when using automated irrigation pumps when compared with manual pumps. 11 …”
Section: Discussionmentioning
confidence: 99%
“…Сравнение длительности операции, SFR, осложнений и объёма использованной ирригационной жидкости с использованием ручной помпы и автоматической ирригационной системы не показало преимуществ одного метода над другим [81,82]. Для полного понимания влияния раз-личных методов ирригации на результаты лечения необходимы дополнительные исследования.…”
Section: ирригацияunclassified