1998
DOI: 10.1002/jmri.1880080509
|View full text |Cite
|
Sign up to set email alerts
|

Prospective evaluation of peripheral arterial occlusive disease by 2D MR subtraction angiography

Abstract: The purpose of this study was to assess the diagnostic value of two-dimensional (2D) MR subtraction angiography of lower extremities in patients with symptomatic peripheral arterial occlusive disease with conventional angiography as the standard of reference. Twenty patients were prospectively included. 2D subtraction MR angiography (MRA) consisted of multisection gradient-recalled echo (GRE) acquisitions with the shortest TE available on our machine (4 msec), obtained in the coronal plane before and after int… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2000
2000
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 19 publications
0
13
0
Order By: Relevance
“…Gd CE MRA has potential to replace conventional X-ray MRA as diagnostic imaging modality for peripheral arterial examinations [7][8][9][10][11][12][13]. With MRA, 3D information about lesions can be obtained while with standard X-ray angiography, arteries can only be visualized in 2D projections.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Gd CE MRA has potential to replace conventional X-ray MRA as diagnostic imaging modality for peripheral arterial examinations [7][8][9][10][11][12][13]. With MRA, 3D information about lesions can be obtained while with standard X-ray angiography, arteries can only be visualized in 2D projections.…”
Section: Resultsmentioning
confidence: 99%
“…Several studies have addressed the advantages and limitations of Gd CE MRA in clinical practice by comparing the diagnostic value of MRA with conventional X-ray angiography [7][8][9][10][11][12][13]. In general, stenoses were graded visually and classified by several observers on both the MR angiograms and the X-ray angiograms.…”
Section: Introductionmentioning
confidence: 99%
“…9,28,36,46,49,51,53,61,65,67,68,70,73,76 The results are reported by the anatomy assessed and the full set of diagnostic accuracy results is presented in Table 6.…”
Section: Ce Mramentioning
confidence: 99%
“…28,49,51,61,67,68,73 The sensitivity of CE MRA ranged from 92% (for two studies with specificities of 64% and 97%) to 99.5% (specificity 99%). The specificity ranged from 64% (sensitivity 92%) to 99% (for two studies with sensitivities of 97% and 99.5%).…”
Section: Whole Legmentioning
confidence: 99%
“…Twenty articles 37,82,92,93,95,[127][128][129][130][131][132][133][134][135][136][137][138][139][140][141] from the peripheral vascular disease part of the review satisfied all the final inclusion criteria. Where results from these articles exactly fitted the dichotomies for our quantitative meta-analyses, they were included in the analyses, and results are given in chapter 6.…”
Section: Peripheral Vascular Diseasementioning
confidence: 99%