2004
DOI: 10.1111/j.1538-7836.2004.00910.x
|View full text |Cite
|
Sign up to set email alerts
|

Proposals for the measurement of anti‐β2‐glycoprotein I antibodies. Standardization Group of the European Forum on Antiphospholipid Antibodies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
93
0
2

Year Published

2010
2010
2017
2017

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 138 publications
(98 citation statements)
references
References 13 publications
0
93
0
2
Order By: Relevance
“…4 In 2004, consensus guidelines and proposals for measurement of aCL and ab2GPI provided advice on sample type, calculation of cut-off values and interpretation of results. 5,6 Recently, a detailed protocol for the performance of aCL enzyme-linked immunosorbent assays (ELISA) 7 and an international consensus guideline on aCL and ab2GPI were published. 8 …”
Section: Introductionmentioning
confidence: 99%
“…4 In 2004, consensus guidelines and proposals for measurement of aCL and ab2GPI provided advice on sample type, calculation of cut-off values and interpretation of results. 5,6 Recently, a detailed protocol for the performance of aCL enzyme-linked immunosorbent assays (ELISA) 7 and an international consensus guideline on aCL and ab2GPI were published. 8 …”
Section: Introductionmentioning
confidence: 99%
“…APS wants to be pregnant again, pre-conceptional treatment deserves consideration 42 . Some women with APS may need life-long warfarin treatment.…”
Section: Antiphospholipid Syndrome In Pregnancy 169mentioning
confidence: 99%
“…It is recommended for each laboratory to establish in-house cut-off values obtained on a population of healthy volunteers with local reagent/instruments combination. 5,6,8,9 The aim of this study was to evaluate the upper limit reference ranges (99 th percentile) used for aCL and a-b2GPI in northwest Italy and to assess the analytical performances of these assays by using normal reference ranges obtained from our own cohort of subjects with and without APS.…”
Section: Introductionmentioning
confidence: 99%
“…These new assays have good analytical performances, excellent intra-assay variation (<10% CV) and may thus reduce the variability between laboratories -a major problem with ELISA kits. [3][4][5][6][7][8][9] However, even with these new platforms, the cut-off values for aCL and a-b2GPI must be carefully chosen, since the diagnostic performance strongly depends on the Correspondence to: B Montaruli, Laboratorio Analisi, AO Ordine Mauriziano, Largo Turati 62, 10128 Turin, Italy Email: bmontaruli@mauriziano.it upper limit reference ranges. It is recommended for each laboratory to establish in-house cut-off values obtained on a population of healthy volunteers with local reagent/instruments combination.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation