2017
DOI: 10.1016/j.applthermaleng.2016.09.061
|View full text |Cite
|
Sign up to set email alerts
|

Proposal of a decision scheme for installing a cogeneration system considering disaster risks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…As can be seen from the studies that used this method, it has been used to obtain an optimum solution for the problems, which are occurred with the application of new energy sources, such as optimum operating cost and strategy, evaluating equipment performance. This method was not only used based on a single objective, which is generally minimizing total annual cost [20], [19]- [24], [31], [34], [36]- [38] and [39], but also it was used based on multi-objective such as ton minimize the costs and to maximize demand satisfaction [30], minimizing the total annual carbon dioxide emissions/ minimizing the global environmental impact/minimizing the costs [25,32], total cost of system and CO2 emission [33], the trade-off between the economic and environmental aspects [27].…”
Section: The Use Of Ie and Or Methodologies And Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As can be seen from the studies that used this method, it has been used to obtain an optimum solution for the problems, which are occurred with the application of new energy sources, such as optimum operating cost and strategy, evaluating equipment performance. This method was not only used based on a single objective, which is generally minimizing total annual cost [20], [19]- [24], [31], [34], [36]- [38] and [39], but also it was used based on multi-objective such as ton minimize the costs and to maximize demand satisfaction [30], minimizing the total annual carbon dioxide emissions/ minimizing the global environmental impact/minimizing the costs [25,32], total cost of system and CO2 emission [33], the trade-off between the economic and environmental aspects [27].…”
Section: The Use Of Ie and Or Methodologies And Resultsmentioning
confidence: 99%
“…CHP and CHCP applications in healthcare facilities generally are working depending on the grid electricity system and natural gas as fuel input. In many relevant studies, various solution methods have been applied for the purpose of obtaining minimum operating cost, optimal operating method and ensuring maximum efficiency for these systems, whereas some studies have proposed to put forth a framework related to comparing of application of these systems for healthcare facilities and equivalent buildings such as hotel, office and shop center [39,55,56,57,58].…”
Section: Alternative Energy Technologies/sources and Resultsmentioning
confidence: 99%
“…The constant human activity that takes place in these buildings and the numerous people who are working or moving into these structures make proper energy management a necessity. Furthermore, energy management in hospitals is an important factor since its mismanagement leads to an increase in operating costs, a negative environmental impact, and a decrease in competitiveness [7]. However, the medical devices used in intensive care units (ICU), surgery rooms, imaging units, and furnaces also require large amounts of energy for smooth functioning.…”
Section: Introductionmentioning
confidence: 99%