2009 Brazilian Power Electronics Conference 2009
DOI: 10.1109/cobep.2009.5347694
|View full text |Cite
|
Sign up to set email alerts
|

Proposal of a 5kVA single-phase on-line UPS with high frequency isolation and power factor correction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…Based on typical online UPS system, a cluster of improved online UPS systems are proposed during the decades, who are more skilled at regulating active power to achieve unity power factor [9]- [13]. Additional DC/DC [9], [10], high frequency transformer [11], [12] and modular structure are three main issues that are chosen to achieve a cost-effective, volume-effective and more reliable online UPS system [13].…”
Section: Proposed Control Scheme For Online Ups Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on typical online UPS system, a cluster of improved online UPS systems are proposed during the decades, who are more skilled at regulating active power to achieve unity power factor [9]- [13]. Additional DC/DC [9], [10], high frequency transformer [11], [12] and modular structure are three main issues that are chosen to achieve a cost-effective, volume-effective and more reliable online UPS system [13].…”
Section: Proposed Control Scheme For Online Ups Systemmentioning
confidence: 99%
“…k_avr , G v_rec , δ k_rec , δ kref , δ a_avr and G ph_rec as restoration value of voltage amplitude, phase order (a, b, c), RMS voltage reference in central controller, averaged value of each phase RMS voltage value, voltage compensation block transfer function, phase restoration value of voltage phase, phase reference in central controller (utility phase angle), averaged value of phase angle and phase compensation blocks transfer function respectively,In this scenario, the compensation blocks are implemented by using two typical PIs, shown in(12) and(13),…”
mentioning
confidence: 99%
“…With the development of power electronic devices, the high-frequency isolation gradually becomes the most important isolation scheme for next generation power electronic converters due to its weight and volume reduction. Then several UPSs with this newly introduced characteristic have been proposed [20]- [28].…”
Section: Introductionmentioning
confidence: 99%
“…The UPS, which adds a dc/dc boost circuit and a dc/dc charger to the topology in Fig. 4, was proposed in [27]- [28], the simplified diagram can be shown in Fig. 5.…”
Section: Introductionmentioning
confidence: 99%