2020
DOI: 10.1016/j.solener.2020.05.083
|View full text |Cite
|
Sign up to set email alerts
|

Proposal and evaluation of typical illuminance year (TIY) generation procedures from illuminance or irradiance data for daylight assessment in the long term

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 42 publications
0
2
0
Order By: Relevance
“…The resulting TMY data set contains measured and/or modeled time series of solar radiation and surface meteorological data, though some hourly records might contain filled or interpolated data for periods when original observations are missing from the data archive. Further, there are many methods used to develop TMMs, as reviewed in and García et al (2020). Novel TMY approaches include a stochastic method (Remund et al 2012), the generation of TMYs at high temporal resolution (Ernst and Gooday 2019), the preparation of TMYs specifically tailored for PV applications , or even customized TMYs (Sengupta, Habte, and Freeman 2019).…”
Section: Long-term and Typical Meteorological Data Setsmentioning
confidence: 99%
“…The resulting TMY data set contains measured and/or modeled time series of solar radiation and surface meteorological data, though some hourly records might contain filled or interpolated data for periods when original observations are missing from the data archive. Further, there are many methods used to develop TMMs, as reviewed in and García et al (2020). Novel TMY approaches include a stochastic method (Remund et al 2012), the generation of TMYs at high temporal resolution (Ernst and Gooday 2019), the preparation of TMYs specifically tailored for PV applications , or even customized TMYs (Sengupta, Habte, and Freeman 2019).…”
Section: Long-term and Typical Meteorological Data Setsmentioning
confidence: 99%
“…Figure 12 shows the distribution of illumination on the rear wall, with the highest illumination reaching 7.62×10 5 Lux, and the lowest value reaching 3.05×10 5 Lux. According to Umberto Berardi [16] and Ignacio García [17], when the indoor illumination reaches 2000 Lux, it can realize normal activities under human vision. When it exceeds 10 5 Lux, it is close to the illuminance under direct sunlight outside the greenhouse.…”
Section: Effect Of Concentrating System On Illuminance In Greenhousementioning
confidence: 99%