2017
DOI: 10.1049/iet-rpg.2016.0857
|View full text |Cite
|
Sign up to set email alerts
|

Proportional‐resonant control applied on voltage regulation of standalone SEIG for micro‐hydro power generation

Abstract: This study deals with the development of a proportional-resonant (PR) control applied on voltage regulation and harmonics compensation of a standalone self-excited induction generator (SEIG) for micro-hydro power generation system. The generation system considers: (i) a three-phase induction generator (IG) as SEIG, (ii) which is driven by an unregulated microhydro turbine, (iii) a three-phase three-legs distribution static synchronous compensator (DSTATCOM) and (iv) linear and nonlinear loads connected to the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
21
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(22 citation statements)
references
References 48 publications
1
21
0
Order By: Relevance
“…Thereby new techniques and techniques already used for harmonic attenuation can be implemented for harmonic mitigation on synchronous generators operating in parallel with squirrel cage induction generators in nonsinusoidal regime. Such publications can be adapted to continue this research line for harmonic reduction in the isolated system proposed here.…”
Section: Additional Commentsmentioning
confidence: 99%
“…Thereby new techniques and techniques already used for harmonic attenuation can be implemented for harmonic mitigation on synchronous generators operating in parallel with squirrel cage induction generators in nonsinusoidal regime. Such publications can be adapted to continue this research line for harmonic reduction in the isolated system proposed here.…”
Section: Additional Commentsmentioning
confidence: 99%
“…. , 8) in Table I, should have at least one element less than zero. As the load increases, when its impedance reaches a certain value, the system is in a critical state between instability and stability.…”
Section: The Routh Criterion For Predicting Self-excited Induction Gementioning
confidence: 99%
“…. , 8) in Table I changes from being not all positive to completely positive, is the maximum load the self-excited induction generator can carry.…”
Section: The Routh Criterion For Predicting Self-excited Induction Gementioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, reducing the torque pulsation is essential to improve the torque performance of the DRPMSM drive system in single-redundancy operation mode. In order to overcome the torque ripple caused by the current of short-circuited coils and improve the performance of the single-redundancy operation of the DRPMSM, this paper firstly proposes an electromagnetic torque ripple suppression strategy for the DRPMSM, based on the proportional resonant (PR) controller [28,29]. When a coils short circuit fault occurs and the DRPMSM shifts into single-redundancy operation mode, the PR controller is paralleled with the proportional integral (PI) controller in the speed loop to suppress the electromagnetic torque ripple output.…”
Section: Introductionmentioning
confidence: 99%