2008
DOI: 10.1002/elan.200704092
|View full text |Cite
|
Sign up to set email alerts
|

Properties of Poly(sodium 4‐styrenesulfonate)‐Ionic Liquid Composite Film and Its Application in the Determination of Trace Metals Combined with Bismuth Film Electrode

Abstract: A new kind of bismuth film modified electrode to sensitively detect trace metal ions based on incorporating highly conductive ionic liquids 1-butyl-3-methyl-imidazolium hexafluorophosphate (BMIMPF 6 ) in solid matrices at glassy carbon (GC) was investigated. Poly(sodium 4-styrenesulfonate) (PSS), silica, and Nafion were selected as the solid matrices. The electrochemical properties of the mixed films modified GC were evaluated. The electron transfer rate of Fe(CN) 6 4À /Fe(CN) 6 3À can be effectively improved … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0
2

Year Published

2008
2008
2014
2014

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(21 citation statements)
references
References 44 publications
0
19
0
2
Order By: Relevance
“…The stability of the ionophore and the ability of the Nafion to extract cations into the membrane, along with the excellence of bismuth film endow an electrode that possesses high precision and accuracy. The GC=NA-IONO=BiFE achieved a very low detection limit (4.4 Â 10 À11 M) which is much lower than those reported (Jia, et al 2008;Legeai, and Vittori, 2006;Jia, et al 2007). Research in our laboratory is in progress for further utility of GC=NA-IONO=BiFE as a flow-through sensor for online determination of lead.…”
Section: Discussionmentioning
confidence: 58%
See 1 more Smart Citation
“…The stability of the ionophore and the ability of the Nafion to extract cations into the membrane, along with the excellence of bismuth film endow an electrode that possesses high precision and accuracy. The GC=NA-IONO=BiFE achieved a very low detection limit (4.4 Â 10 À11 M) which is much lower than those reported (Jia, et al 2008;Legeai, and Vittori, 2006;Jia, et al 2007). Research in our laboratory is in progress for further utility of GC=NA-IONO=BiFE as a flow-through sensor for online determination of lead.…”
Section: Discussionmentioning
confidence: 58%
“…Recently, mixed polymeric coatings on GC electrodes were reported to improve the performances of Nafion coatings (Jia, et al 2008;Monterroso, et al 2006;Leelasattarathkul, et al 2007;Rocha, et al 2006;Brett, et al 1999;Brett, et al 2001). A Nafion-coated GC electrode modified by neutral ionophore has been reported for simultaneously determine Pb(II), Cu(II), and Hg(II) (Chen, et al 1999).…”
Section: Introductionmentioning
confidence: 99%
“…Ionogels represent an interesting approach also for the detection of ions and metal oxides by voltammetric methods such as stripping voltammetry (322), thanks to their solvation properties (323). For example, Wan et al (319) incorporated thiols to improve the stability of bucky-gels on carbon electrodes and then used the modified electrodes to detect lead ions by means of stripping voltammetry.…”
Section: Biomedical Applications Of Ionogelsmentioning
confidence: 99%
“…45 Estudos realizados comprovam que os BFE apresentam elevada sensibilidade, um sinal bem definido e altamente reprodutível, um grande intervalo de potencial catódico, uma boa resolução de picos vizinhos, e ainda são menos sensíveis do que os MFE ao oxigénio dissolvido. 43,44,[46][47][48] No entanto, a vantagem mais significativa dos BFEs é que a toxicidade do Bi é negligenciá-vel, ao contrário da extrema toxicidade do Hg usado na preparação dos MFEs. 41,44,45,47,49,50 Recentemente, encontram-se alguns trabalhos visando a determinação de metais por voltametria de redissolução em BFEs, [51][52][53] sendo no entanto escassos os trabalhos desenvolvidos tendo em vista a especiação dos mesmos em BFEs.…”
Section: Importância Da Determinação De Metais Em Amostras Biológicasunclassified