Proceedings of the IGSHPA Technical/Research Conference and Expo 2017 2017
DOI: 10.22488/okstate.17.000518
|View full text |Cite
|
Sign up to set email alerts
|

Properties of Different Ethyl Alcohol Based Secondary Fluids Used for GSHP in Europe and Usa

Abstract: The extensive use of ground source heat pumps (GSHP)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 4 publications
0
1
0
Order By: Relevance
“…Subsurface temperatures were recorded with the use of 4 PT-100 thermistors that have a measuring range between 10 °C to 200 °C and an accuracy of: ±1°C. Additionally, it is taken into account the use of an aqueous solution of ethyl alcohol to reduce the freezing point of the secondary fluid (Ignatowicz et al, 2017).…”
Section: Methodsmentioning
confidence: 99%
“…Subsurface temperatures were recorded with the use of 4 PT-100 thermistors that have a measuring range between 10 °C to 200 °C and an accuracy of: ±1°C. Additionally, it is taken into account the use of an aqueous solution of ethyl alcohol to reduce the freezing point of the secondary fluid (Ignatowicz et al, 2017).…”
Section: Methodsmentioning
confidence: 99%
“…Subsurface temperatures were recorded with the use of 4 PT-100 thermistors that have a measuring range between 10 °C to 200 °C and an accuracy of: ±1°C. Additionally, it is taken into account the use of an aqueous solution of ethyl alcohol to reduce the freezing publishing José David Barros Enríquez et al -Design of a cooling system from underground thermal energy storage (UTES, Underground) Thermal Energy Storage) based on experimental results 387 point of the secondary fluid [10]. Once the measurements of the sensors were collected, they were tabulated (Table 1) and graphed where it was possible to verify that, according to [11], the temperature variation decreases with depth.…”
Section: Methodsmentioning
confidence: 99%
“…As the most conventional GSHP secondary fluid in Europe (Ignatowicz et al, 2017), an aqueous ethanol solution of 24% weight concentration is used as the heat-carrier fluid for geothermal loops. It has a freezing temperature of -14.6 ºC; however, its operating temperature Tf [°C] is restricted to be within the range of -5°C and +20°C.…”
Section: Geothermal Storage and Gshp Hybrid Solutionmentioning
confidence: 99%