2017
DOI: 10.1140/epja/i2017-12353-y
|View full text |Cite
|
Sign up to set email alerts
|

Prompt-delayed $\gamma$ γ -ray spectroscopy with AGATA, EXOGAM and VAMOS++

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
32
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2

Relationship

4
4

Authors

Journals

citations
Cited by 26 publications
(36 citation statements)
references
References 44 publications
3
32
0
Order By: Relevance
“…The lifetime τ (2 + 1 ) = 1.3(5) ps of the 2 + 1 state in 54 Ti determined in this work corresponds to a reduced transition probability of B(E 2; 2 + 1 → 0 + gs ) = 84 +53 −23 e 2 fm 4 and agrees with the adopted lifetime τ (2 + 1 ) = 1.53 (27) ps with corresponding B(E 2; 2 + 1 → 0 + gs ) = 72 +15 −11 e 2 fm 4 [9] within their error limits.…”
Section: Data Analysis and Resultssupporting
confidence: 84%
See 1 more Smart Citation
“…The lifetime τ (2 + 1 ) = 1.3(5) ps of the 2 + 1 state in 54 Ti determined in this work corresponds to a reduced transition probability of B(E 2; 2 + 1 → 0 + gs ) = 84 +53 −23 e 2 fm 4 and agrees with the adopted lifetime τ (2 + 1 ) = 1.53 (27) ps with corresponding B(E 2; 2 + 1 → 0 + gs ) = 72 +15 −11 e 2 fm 4 [9] within their error limits.…”
Section: Data Analysis and Resultssupporting
confidence: 84%
“…1 of Ref. [27] (without the EXOGAM detectors). The focal plane detection system was used to identify the mass (A), charge (Q) and atomic number (Z) of the reaction products.…”
Section: -2mentioning
confidence: 99%
“…Gamma-ray interaction points, determined by Pulse Shape Analysis (PSA) and GRID search algorithm techniques, were tracked by using the Orsay Forward Tracking (OFT) algorithm, as described in Ref. [32]. The delayed γ rays (γ D ) were detected by using seven EXOGAM HPGe Clover detectors [33], arranged in a wall-like configuration at the focal plane of VAMOS++.…”
Section: Methodsmentioning
confidence: 99%
“…The particle identification (PID) spectra, intrinsic resolutions of the spectrometer ( Z/Z, A/A, q/q), and additional experimental details are given in Ref. [32].…”
Section: Methodsmentioning
confidence: 99%
“…Further details on VAMOS++ along with typical performances for the fission-fragments detection are given in Refs. [34,36,37]. Figure 1(a) shows the identification spectrum of targetlike ions, detected in coincidence with fission fragments, obtained from the correlation of the energy loss and the total energy, measured in SPIDER.…”
mentioning
confidence: 99%