Prolonged heating in nontargeted tissue during MR‐guided focused ultrasound of bone tumors

Abstract: Background Thermal dosimetry during MR‐guided focused ultrasound (MRgFUS) of bone tumors underpredicts ablation zone. Intraprocedural understanding of heat accumulation near bone is needed to prevent undesired treatment of nontargeted tissue. Hypothesis Temperature decay rates predict prolonged, spatially varying heating during MRgFUS bone treatments. Study Type Prospective case series. Patients Nine patients with localized painful bone tumors (five bone metastasis, four osteoid osteomas), were compared with f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 33 publications
(54 reference statements)
0
5
0
Order By: Relevance
“…SPSS software (V.25, Inc, Chicago, IL, USA) was used for data analysis. Numeric data were tested for normality using the Kolmogorov–Smirnov test (Bitton et al, 2019), skewness and kurtosis statistics, as well as visual inspection of histograms and probability–probability plots. After the Kolmogorov–Smirnov test, the result was significant ( p < .05).…”
Section: Methodsmentioning
confidence: 99%
“…SPSS software (V.25, Inc, Chicago, IL, USA) was used for data analysis. Numeric data were tested for normality using the Kolmogorov–Smirnov test (Bitton et al, 2019), skewness and kurtosis statistics, as well as visual inspection of histograms and probability–probability plots. After the Kolmogorov–Smirnov test, the result was significant ( p < .05).…”
Section: Methodsmentioning
confidence: 99%
“…With interleaved MRT, it becomes possible to monitor complex heating behavior. In our experiment, this approach allowed to detect temperature change caused by transfer of heat generated by the intersection of the ultrasound beam with the cortex 27 into the tissues surrounding the focal area.…”
Section: Discussionmentioning
confidence: 99%
“…Non-accurate targeting may lead to undertreatment or overtreatment of the target bone. 28 As noted earlier, EDBS is an important supplement to PRF thermometry, and it is hoped that this parameter will be better incorporated into future MRgFUS software platforms.…”
Section: Painful Bone Metastasesmentioning
confidence: 97%