2021
DOI: 10.1007/978-3-030-90788-4_30
|View full text |Cite
|
Sign up to set email alerts
|

Progressive Collapse Retrofit of a RC Hospital Building Using Steel Braces

Abstract: The progressive collapse retrofit of a RC hospital building making use of steel braces is described in the paper. The vulnerability of the construction when subjected to specific threat scenarios is preliminary analysed by removing critical column and applying the alternate load path method to evaluate the capability of the damaged structure to bridge across the removed column. A detailed threedimensional model of the building has been created to carry out both nonlinear static and nonlinear dynamic analyses. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…Due to removal of the above two columns, the behavior of the horizontal beams connected with them changes drastically: These beams are not working further as "continuous beams", although they had been designed and constructed as such ones. So, after a structural assessment by a "push-over" methodology [4,5,13,15,26] and 10 incremental dynamic analysis (IDA) procedures [14,[33][34][35][36][37] of the system F0 under uncertainty and the shown critical loading system, it is concluded that the initial RC frame F0 of Fig. 2 is under a significant risk for a progressive collapse.…”
Section: Fig 2 System F0: the Initial Rc Frame (Without Cables-streng...mentioning
confidence: 99%
See 1 more Smart Citation
“…Due to removal of the above two columns, the behavior of the horizontal beams connected with them changes drastically: These beams are not working further as "continuous beams", although they had been designed and constructed as such ones. So, after a structural assessment by a "push-over" methodology [4,5,13,15,26] and 10 incremental dynamic analysis (IDA) procedures [14,[33][34][35][36][37] of the system F0 under uncertainty and the shown critical loading system, it is concluded that the initial RC frame F0 of Fig. 2 is under a significant risk for a progressive collapse.…”
Section: Fig 2 System F0: the Initial Rc Frame (Without Cables-streng...mentioning
confidence: 99%
“…Recently, the use of cable-like members (tension-only ties) has been considered as an alternative strengthening method [6,7,16,[31][32][33][34]. As well-known, ties have been used effectively in monastery buildings and churches arches.…”
Section: Introductionmentioning
confidence: 99%