2023
DOI: 10.3390/life13091871
|View full text |Cite
|
Sign up to set email alerts
|

Progression of Rare Inherited Retinal Dystrophies May Be Monitored by Adaptive Optics Imaging

Katarzyna Samelska,
Jacek Paweł Szaflik,
Barbara Śmigielska
et al.

Abstract: Inherited retinal dystrophies (IRDs) are bilateral genetic conditions of the retina, leading to irreversible vision loss. This study included 55 eyes afflicted with IRDs affecting the macula. The diseases examined encompassed Stargardt disease (STGD), cone dystrophy (CD), and cone–rod dystrophy (CRD) using adaptive optics (Rtx1™; Imagine Eyes, Orsay, France). Adaptive optics facilitate high-quality visualisation of retinal microstructures, including cones. Cone parameters, such as cone density (DM), cone spaci… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 35 publications
(59 reference statements)
0
1
0
Order By: Relevance
“…The image dimensions are 4 • × 4 • , representing 1.2 mm × 1.2 mm of the retina. Image acquisition in a single position lasts approximately 4 s, during which 40 individual images are acquired [22,24]. The Rtx1™ software provides the program AO Detect Artery to analyse retinal vessel parameters and correct distortions within frames [22,25].…”
Section: Examinationmentioning
confidence: 99%
“…The image dimensions are 4 • × 4 • , representing 1.2 mm × 1.2 mm of the retina. Image acquisition in a single position lasts approximately 4 s, during which 40 individual images are acquired [22,24]. The Rtx1™ software provides the program AO Detect Artery to analyse retinal vessel parameters and correct distortions within frames [22,25].…”
Section: Examinationmentioning
confidence: 99%
“…The ability to evaluate the retina at a cellular level highlights new anatomical readouts that can be used to evaluate the ability of 2D and 3D cultures to mimic the retina. These parameters include cellular density, spacing, and regularity ( 124 , 125 ). These insights can further guide the development of organoid or retina-on-a-chip technologies for more accurate biological representation.…”
Section: Technology Hurdles and Future Directionsmentioning
confidence: 99%
“…The image dimensions are 4∘ × 4∘, representing 1.2 mm × 1.2 mm of the retina. Image acquisition in a single position lasts approximately 4 s, during which 40 individual images are acquired [25]. The Rtx1™ software provides the program AO Detect Artery to analyse retinal vessel parameters and correct distortions within frames [26].…”
Section: Examinationmentioning
confidence: 99%