2019
DOI: 10.3788/lop56.080004
|View full text |Cite
|
Sign up to set email alerts
|

Progress of Interactive Holographic Display

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 0 publications
0
1
0
Order By: Relevance
“…(1) according to the experimental requirements, after the target muscle to be sampled is fixed, the electrodes are applied in pairs [159]; (2) the electrode is evenly distributed on the skin surface in a ring structure according to a certain law; and (3) the electrodes are closely arranged to collect the EMG information in all directions [160]. In addition, studies have shown that a stronger EMG signal can be obtained by placing the sensing electrode in the muscle belly and a weaker EMG signal can be obtained by placing the electrode at the edge of the tendon or muscle group [161].…”
Section: Manipulator Control Application Based On Surface Emg Signalmentioning
confidence: 99%
See 3 more Smart Citations
“…(1) according to the experimental requirements, after the target muscle to be sampled is fixed, the electrodes are applied in pairs [159]; (2) the electrode is evenly distributed on the skin surface in a ring structure according to a certain law; and (3) the electrodes are closely arranged to collect the EMG information in all directions [160]. In addition, studies have shown that a stronger EMG signal can be obtained by placing the sensing electrode in the muscle belly and a weaker EMG signal can be obtained by placing the electrode at the edge of the tendon or muscle group [161].…”
Section: Manipulator Control Application Based On Surface Emg Signalmentioning
confidence: 99%
“…(1) Cost problem of the data glove: although there are already many data-glove products in the market, and researchers are constantly innovating in this field, data glove will incur a lot of costs during the production process, including the cost of materials required to manufacture the glove itself and the flexible sensor and the cost of external circuit boards or some other hardware production, which makes it difficult to put this device into practical use in large numbers. In the future, the cost of using data gloves will be reduced and their development in the market will be more convenient; (2) The category bottleneck problem of manual movement information collected by the data glove: the generation of an electromyographic signal is due to the hungry excitation of the cerebral cortex, while the manual movement information collected by the data glove is the pressure or angle change generated when the gesture changes, obviously the electromyographic signal is more abundant; (3) Improving the sensitivity/accuracy: first of all, the type of material used has an impact on its accuracy. For strain sensors, the better the piezoresistive properties of the material, the better the performance of the sensor; for pressure sensors, the electrical conductivity of the materials greatly affects the accuracy of signal conversion in collecting useful information and, then, affects the accuracy of detection.…”
Section: Manipulator Control System Problemsmentioning
confidence: 99%
See 2 more Smart Citations
“…), and interactivity (including touch, [ 7 ] gesture, [ 8 ] voice, [ 9 ] and other interaction methods. [ 10 ] ). In addition, novel display technologies with stereoscopic information have become important development directions of display technology.…”
Section: Introductionmentioning
confidence: 99%