2020
DOI: 10.3390/s21010017
|View full text |Cite
|
Sign up to set email alerts
|

Programable Active Fixator System for Systematic In Vivo Investigation of Bone Healing Processes

Abstract: This manuscript introduces a programable active bone fixator system that enables systematic investigation of bone healing processes in a sheep animal model. In contrast to previous systems, this solution combines the ability to precisely control the mechanical conditions acting within a fracture with continuous monitoring of the healing progression and autonomous operation of the system throughout the experiment. The active fixator system was implemented on a double osteotomy model that shields the experimenta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 41 publications
0
7
0
Order By: Relevance
“…Our group recently developed a system [ 41 ] for the continuous measurement of repair tissue stiffness. Using this model, we can assess the mechanical competence of fracture repair tissue without sacrificing multiple animals at different time points.…”
Section: Discussionmentioning
confidence: 99%
“…Our group recently developed a system [ 41 ] for the continuous measurement of repair tissue stiffness. Using this model, we can assess the mechanical competence of fracture repair tissue without sacrificing multiple animals at different time points.…”
Section: Discussionmentioning
confidence: 99%
“…The motion of the active fixator was regulated by a custom-made control unit [19] that was directly attached to the fixator frame and which autonomously executed the programmed stimulation protocol. For each stimulation cycle, the displacement of the mobile bone fragment and the corresponding force was measured and the data was recorded in the internal memory of the control unit.…”
Section: Methodsmentioning
confidence: 99%
“…The study was approved by the local ethics committee (Canton of Grisons, Switzerland, approval: TVB 2017_23, 01/09/2017 and conducted under our AAALAC accredited roof. The surgeries were performed on the right The motion of the active fixator was regulated by a custom-made control unit [19] that was directly attached to the fixator frame and which autonomously executed the programmed stimulation protocol. For each stimulation cycle, the displacement of the mobile bone fragment and the corresponding force was measured and the data was recorded in the internal memory of the control unit.…”
Section: Animal Experimentsmentioning
confidence: 99%
See 2 more Smart Citations