2000
DOI: 10.1159/000007024
|View full text |Cite
|
Sign up to set email alerts
|

Prognostic Value of Ischemia Monitoring with On-Line Vectorcardiography in Patients with Unstable Coronary Artery Disease

Abstract: Aim: The aim of this study was to determine whether on-line vectorcardiography (VCG) gives independent prognostic information, regarding death, myocardial infarction (MI), and revascularization in patients with unstable coronary artery disease, i.e. unstable angina or non-Q-wave MI. Methods and Results: One hundred and fifty patients (mean age 69 ± 10), participating in a randomized study of low-molecular-weight heparin in unstable coronary artery disease, were studied with on-line VCG recordings for 24 h. Dur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2000
2000
2017
2017

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…In addition, technical or skin-electrode impedance problems during the recording may not be identified, potentially leading to loss of data. In contrast to the Holter monitoring system, newer multilead monitoring devices, i.e., S-T segment monitoring based on the 12-lead ECG [23, 24, 25, 26, 27, 28]or QRS and S-T segment monitoring based on VCG [10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22], have the option of real-time analysis. Moreover, as compared with multilead monitoring systems, there is an inherent risk of reduced sensitivity of Holter monitoring in detecting myocardial ischemia due to the limited number of exploring electrodes, irrespective of how they are positioned [21, 23].…”
Section: Continuous Electrocardiographic Monitoringmentioning
confidence: 99%
See 4 more Smart Citations
“…In addition, technical or skin-electrode impedance problems during the recording may not be identified, potentially leading to loss of data. In contrast to the Holter monitoring system, newer multilead monitoring devices, i.e., S-T segment monitoring based on the 12-lead ECG [23, 24, 25, 26, 27, 28]or QRS and S-T segment monitoring based on VCG [10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22], have the option of real-time analysis. Moreover, as compared with multilead monitoring systems, there is an inherent risk of reduced sensitivity of Holter monitoring in detecting myocardial ischemia due to the limited number of exploring electrodes, irrespective of how they are positioned [21, 23].…”
Section: Continuous Electrocardiographic Monitoringmentioning
confidence: 99%
“…An ischemic episode is defined as a transient change of ST-VM and/or STC-Vm >50 µV >1 min from the individual baseline level [14, 16, 17, 18, 19, 20, 22]. A QRS-VD ischemic episode is defined as a transient change >15 µVs from the patient’s baseline level [11, 12, 13, 18].…”
Section: Continuous Vectorcardiographic Monitoringmentioning
confidence: 99%
See 3 more Smart Citations