Production rates for oxyfluorides SOF2, SO2F2, and SOF4 in SF6 corona discharges

Abstract: The most abundant, long-lived stable gaseous species generated by corona discharges in SF 6 gas containing trace levels of 0, and H,0 are the oxyfluorides SOF,, SOF, and SOF 4 . Absolute energy and charge rates-ofproduction of these and the minor products SO,, OCS, and CO2 have been measured at different total gas pressures from 100 kPa to 300 kPa and for discharges of different current, power, and polarity. Oxyfluoride yields for SF6/02 mixtures containing up to 10% 0, have also been measured. The results ind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
68
1

Year Published

1989
1989
2018
2018

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 108 publications
(78 citation statements)
references
References 40 publications
9
68
1
Order By: Relevance
“…(17) that the time rate-ofproduction for S 2 F 10 is proportional to the discharge current. The fact that the production appears to be linear suggests [31,56] that secondary S 2 F 10 production and destruction processes are relatively unimportant.…”
Section: Calibrationmentioning
confidence: 99%
See 3 more Smart Citations
“…(17) that the time rate-ofproduction for S 2 F 10 is proportional to the discharge current. The fact that the production appears to be linear suggests [31,56] that secondary S 2 F 10 production and destruction processes are relatively unimportant.…”
Section: Calibrationmentioning
confidence: 99%
“…Calculated (lines) [31] and Sauers and coworkers [25]. Figure 16 shows a comparison between the measured and calculated oxyfluoride yields for a fixed discharge current and water vapor concentration and the two different indicated relative 0 2 concentrations.…”
Section: Model Descriptionmentioning
confidence: 99%
See 2 more Smart Citations
“…Eventually, the safe and reliable operation of the equipment and the entire power grid is compromised. SF 6 gas component analysis (GCA) is a non-electrical detection method, which can effectively avoid the complex electromagnetic interference of substations and has become a popular research topic in recent years [13][14][15][16]. In [17][18][19], the SF6 decomposed products under arc, spark, and corona discharges were studied.…”
Section: Introductionmentioning
confidence: 99%