Production of new thermoluminescent mini-dosimeters

Abstract: A method of producing CaSO4:Dy thermoluminescent mini-dosimeters was reported in 1986 by B W Wessels for determination of the in vivo absorbed dose in radioimmunotherapy, a field in which absorbed dose gradients are important. These dosimeters, which undergo dissolution when used in a liquid environment, showed a sensitivity loss of up to 30% after 4 days of immersion in our tests. Moreover, several studies have shown that biocompatibility problems can occur during in vivo studies in animals. This paper descri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
9
0
3

Year Published

2002
2002
2020
2020

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 23 publications
1
9
0
3
Order By: Relevance
“…However, CaSO 4 :Dy crystals are highly hydrophilic and water diffusion, temperature and pH changes alter photoemission responses. 30% of signal is lost after only 4 days of incubation in agarose gel due to crystalline dissolution (Demidecki et al 1993, Strand and Strandh 1994, Martin et al 2000. From the biological point of view, CaSO 4 :Dy mini thermoluminescent dosimeter (TLD) dissolution limited probably biocompatibility (Chiou et al 1991).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, CaSO 4 :Dy crystals are highly hydrophilic and water diffusion, temperature and pH changes alter photoemission responses. 30% of signal is lost after only 4 days of incubation in agarose gel due to crystalline dissolution (Demidecki et al 1993, Strand and Strandh 1994, Martin et al 2000. From the biological point of view, CaSO 4 :Dy mini thermoluminescent dosimeter (TLD) dissolution limited probably biocompatibility (Chiou et al 1991).…”
Section: Introductionmentioning
confidence: 99%
“…In this context, new thermoluminescent dosimeters were developed for internal dosimetry and radioprotection (Martin et al 1999(Martin et al , 2000. Their production process is the extrusion of LiF:Mg,Cu,P and a polypropylene mixture, leading to long threads of 400 µm diameter.…”
Section: Introductionmentioning
confidence: 99%
“…Gy -1 . Fazendo-se uso da equação (3.2) tem-se que a dose absorvida mínima de detecção é de 1,942 mGy, coincidindo este valor com o publicado [Martin, 2000]. Portanto este dosímetro pode ser aplicável para pontos de medidas fora do campo de radiação no CQ postal da radiocirurgia.…”
Section: Iii12 Tldunclassified
“…o Uma das coisas que se deve levar em consideração é o ciclo de reutilização, já que este pode afetar na reprodutibilidade. Assim a temperatura da pré-irradiação e de leitura não deve ser maior do que 240 o C, já que segundo as referências até este valor não se tem a degradação das características dosimétricas do material TL, para este tipo de dosímetro [ Martin (2000), Wang et al (1990)]. Desta maneira, se tem a preservação das características do material TL para a reutilização [ Wang et al (1990)].…”
Section: Fator Pela Presença Do Objeto Simulador IIunclassified
See 1 more Smart Citation