2020
DOI: 10.1016/j.powtec.2020.03.027
|View full text |Cite
|
Sign up to set email alerts
|

Process analytical technology-based (PAT) model simulations of a combined cooling, seeded and antisolvent crystallization of an active pharmaceutical ingredient (API)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
25
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 39 publications
(25 citation statements)
references
References 34 publications
0
25
0
Order By: Relevance
“…To achieve this, the suspension was continuously circulated through the diffractometer cell using a centrifugal pump in a loop configuration (as shown in Figure 2) at a constant flow rate of ∼0.6 L min. 1 Circulation to the diffractometer cell was started right before seed addition to record background measurements as well as in the absence of crystals. It is noted that using this online PSD measurement technique, the operating range in terms of slurry density has to be kept quite low in order to avoid multiple scattering measurement artifacts.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…To achieve this, the suspension was continuously circulated through the diffractometer cell using a centrifugal pump in a loop configuration (as shown in Figure 2) at a constant flow rate of ∼0.6 L min. 1 Circulation to the diffractometer cell was started right before seed addition to record background measurements as well as in the absence of crystals. It is noted that using this online PSD measurement technique, the operating range in terms of slurry density has to be kept quite low in order to avoid multiple scattering measurement artifacts.…”
Section: Methodsmentioning
confidence: 99%
“…The evolution of the PSD during the crystallization experiments, expressed as volume fractions, was recorded in-line (every 5 min) using a laser diffractometer (Malvern Mastersizer 3000). To achieve this, the suspension was continuously circulated through the diffractometer cell using a centrifugal pump in a loop configuration (as shown in Figure ) at a constant flow rate of ∼0.6 L min …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…As an alternative, mechanistic modeling simulations could be used in order to obtain a more comprehensive view of crystalline systems. [58,59]…”
Section: Particle Sizementioning