1996
DOI: 10.1021/jp960951s
|View full text |Cite
|
Sign up to set email alerts
|

Probing the [CoC3H8]+Potential Energy Surface:  A Detailed Guided-Ion Beam Study

Abstract: The potential energy surface for the CoC 3 H 8 + system is examined in studies using a guided-ion beam tandem mass spectrometer in conjunction with a dc discharge/flow tube ion source. Bimolecular reactions of Co + + C 3 H 8 , Co + (C 3 H 6 ) + H 2 (D 2 ), Co + (C 2 H 4 ) + CH 4 (CD 4 ), and CoCH 2 + + C 2 H 6 are examined, as well as threshold collisional activation of Co + (C 3 H 8 ). The results allow details of the [CoC 3 H 8 ] + potential energy surface to be elucidated. A key feature of the potential ene… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
31
0

Year Published

1999
1999
2010
2010

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 27 publications
(40 citation statements)
references
References 44 publications
9
31
0
Order By: Relevance
“…Overall, the energetics predicted in this work appear to be largely in good agreement with experiment, 3 although some discrepancies are observed. Some of the experimental energetics quoted in Table 2 were deduced from figures in that paper, and therefore may not be accurate.…”
Section: Discussionsupporting
confidence: 75%
“…Overall, the energetics predicted in this work appear to be largely in good agreement with experiment, 3 although some discrepancies are observed. Some of the experimental energetics quoted in Table 2 were deduced from figures in that paper, and therefore may not be accurate.…”
Section: Discussionsupporting
confidence: 75%
“…The corresponding value of À 29.0 kcal mol À1 is close to the estimate of 30.9 kcal mol À1 for Co ÀC 3 H 8 binding energy from a threshold collisional activation study. [37] However, interpretation of those experiments is presumably subject to much the same modeling uncertainty that we confront here.…”
Section: Adjustment Of Model Parametersmentioning
confidence: 84%
“…[36] This agrees well with the value 8 % at 0.2 eV from earlier ion beamgas experiments by Armentrout and co-workers. [37] The simple TOF-MS with t ext 8 ms in effect samples the decay kinetics of collision complexes over a uniform distribution of times in the window t 2 ± 10 ms. The resulting prompt product branching fractions including adducts are summarized for two collision energies in Table 1.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations