2010
DOI: 10.1021/om101038t
|View full text |Cite
|
Sign up to set email alerts
|

Probing Cyanocuprates by Electrospray Ionization Mass Spectrometry

Abstract: Supporting InformationTable of Contents 1.) Anion-mode ESI mass spectra recorded with the TSQ 7000 instrument (Figures S1 -S4) S2 2.) Characterization of the HCT ion trap (Figures S5 -S8) S4 3.) Comparison of measured and simulated isotope patterns (Figures S9 -S10) S6

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
9

Relationship

6
3

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Before entering the ion trap, the ions passed a glass capillary (capillary exit: ±20 V), a skimmer (±20 V), and two transfer octopoles (±4.0 V/±1.7 V). As we have shown before, these very mild ESI conditions help to prevent labile organometallic species from unwanted decomposition reactions . The helium‐filled ion trap (estimated pressure p (He) ca.…”
Section: Methodsmentioning
confidence: 99%
“…Before entering the ion trap, the ions passed a glass capillary (capillary exit: ±20 V), a skimmer (±20 V), and two transfer octopoles (±4.0 V/±1.7 V). As we have shown before, these very mild ESI conditions help to prevent labile organometallic species from unwanted decomposition reactions . The helium‐filled ion trap (estimated pressure p (He) ca.…”
Section: Methodsmentioning
confidence: 99%
“…The ESI source was operated at a voltage of ±3000 V with N 2 as nebulizer gas (0.7 bar) and drying gas (5.0 L min −1 , 373 K). To transfer the generated ions into the quadrupole‐ion trap, very mild conditions were applied to prevent unwanted decomposition reactions . The helium‐filled trap [estimated pressure p (He)≈ 0.3 Pa] was typically operated at a trap drive of 40 to ensure efficient trapping and detection of ions of medium m / z ratios (typically recorded m / z range: 50–1000).…”
Section: Experimental and Theoretical Methodsmentioning
confidence: 99%
“…Recently, also organometallic compounds sensitive to air and hydrolysis have been successfully studied via ESI-MS (e.g., cyanocuprates), and new sampling techniques for sensitive compounds were introduced, such that the scope of ESI-MS is likely to be extended to even more fragile metal organyls. Further, ESI can nowadays also be performed at low temperatures .…”
Section: Enthusiasmmentioning
confidence: 99%