Prism-Based Infrared Spectrographs Using Modern-Day Detectors

Abstract: A comparison of prism-based spectrographs to grating-based spectrographs is made when each of the systems is coupled to a modern-day liquid-nitrogen-cooled photovoltaic array detector. A comparison of the systems is also made using a room-temperature microbolometer array detector. Finally, infrared microspectroscopy of samples whose size is approximately 10 micrometers will be demonstrated using a prism spectrograph outfitted with both types of detectors. The results of the study show that prism-based spectrog… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(18 citation statements)
references
References 16 publications
(26 reference statements)
0
18
0
Order By: Relevance
“…Once the data is collected, the corresponding infrared spectra from the 256 3 256 image can be converted from pixel numbers to wavenumbers using a previously reported process. 25 To explain briefly, an infrared spectrum was collected on a sample both interferometrically and also with the PA-IR system. The pixel number absorptions obtained from the PA-IR spectrum were plotted against wavenumber absorptions from the FT-IR spectrum.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Once the data is collected, the corresponding infrared spectra from the 256 3 256 image can be converted from pixel numbers to wavenumbers using a previously reported process. 25 To explain briefly, an infrared spectrum was collected on a sample both interferometrically and also with the PA-IR system. The pixel number absorptions obtained from the PA-IR spectrum were plotted against wavenumber absorptions from the FT-IR spectrum.…”
Section: Resultsmentioning
confidence: 99%
“…PA-IR spectroscopy is gaining acceptance as a viable alternative to FT-IR spectroscopy for many applications. [20][21][22][23][24][25][26][27][28] The emergence of PA-IR spectroscopy can be attributed to its sensitivity, rugged nature (no moving parts), and multichannel detection capabilities for imaging. Most of the current PA-IR systems incorporate either grating or prism-based macro sampling accessories and employ mercury cadmium telluride (MCT) focal plane array detectors.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…There has recently been renewed interest in reflective and prism-based approaches to dispersion. 54,55 Reflective gratings can usually cover a larger range of the spectrum at high spectral resolution, but often result in a longer integration time due to lower efficiency and movement of the grating position. Some devices circumvent this issue by including versatile options for either static or full-range spectral measurements, or include gratings with different dispersion elements to achieve high resolution.…”
Section: Clinical Instrumentationmentioning
confidence: 99%
“…Generally, prism-based spectrographs have the advantage of a higher optical transmission when compared to grating spectrographs, although optimized grating structures [30] can reach diffraction efficiencies up to 80%. Prisms are deployed when spectral width rather than spectral resolution is demanded [31]. In addition, they do not suffer from order effects and stray light.…”
Section: Optics Designmentioning