2020
DOI: 10.1016/j.ejmp.2020.10.014
|View full text |Cite
|
Sign up to set email alerts
|

Principles and applications of dual source CT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(49 citation statements)
references
References 54 publications
(55 reference statements)
0
44
0
Order By: Relevance
“…The key feature of the high‐pitch mode DSCT is its improved temporal resolution 26 . The third‐generation DSCT turbo FLASH mode temporal resolution can be up to 66 ms with the highest pitch of 3.2 and SFOV of Ø 35.4 cm, and it is suitable for conditions requiring high temporal resolution and no large SFOV, like cardiovascular CT imaging, 8,27–29 and nonobese patient or pediatrics imaging 1,30,31 .…”
Section: Discussionmentioning
confidence: 99%
“…The key feature of the high‐pitch mode DSCT is its improved temporal resolution 26 . The third‐generation DSCT turbo FLASH mode temporal resolution can be up to 66 ms with the highest pitch of 3.2 and SFOV of Ø 35.4 cm, and it is suitable for conditions requiring high temporal resolution and no large SFOV, like cardiovascular CT imaging, 8,27–29 and nonobese patient or pediatrics imaging 1,30,31 .…”
Section: Discussionmentioning
confidence: 99%
“…The biggest advantages of dual-source scanners are their extraordinarily high temporal resolution up to 66 ms when operating in single-energy mode [ 17 ] and their ability to independently modulate currents to reduce radiation doses and install filters in order to increase the energy separation of emitted photons [ 5 , 9 , 26 , 27 ]. The temporal resolution in dual-energy mode is not so extraordinary but is still high—125 ms [ 17 , 28 ].…”
Section: Types Of Dect Scanners From Different Manufacturersmentioning
confidence: 99%
“…The shift of tubes causes a minimal delay of registration data from the same location of both lamps, which can generate misregistration artifacts [ 29 , 30 ]. Moreover, scatter photons that originate in one tube can reach the detector of another and generate artifacts [ 27 , 29 ].…”
Section: Types Of Dect Scanners From Different Manufacturersmentioning
confidence: 99%
“…The dual-source CT (DSCT) is a new technology developed based on 64-slice spiral CT. DSCT with two x-ray tubes and two detectors and the systems can work simultaneously ( 53 ). DSCT improves temporal resolution compared to single-source CT, which allows for imaging at higher heart rates.…”
Section: Current Clinically Available Ct Techniquesmentioning
confidence: 99%