1973
DOI: 10.1016/s0030-5898(20)30822-1
|View full text |Cite
|
Sign up to set email alerts
|

Primary Repair of Flexor Tendons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
26
0
11

Year Published

1999
1999
2013
2013

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 327 publications
(38 citation statements)
references
References 6 publications
1
26
0
11
Order By: Relevance
“…Verdan (1960) managed the adhesion problem by cross pins through the tendon at a distance from the cut and a fine 'arterial' peripheral suture (Figure 1(C)); the sheath at the repair site was excised for 2.5 cm to prevent adhesion. Kleinert et al (1973) used a short criss-cross core suture (essentially a short Bunnell suture) and a peripheral suture, with fine 5-0 and 6-0 sutures, respectively (Figure 1(D)). Kleinert et al (1981) later reported the modified Kessler core suture and used 3-0 braided polyester and 4-0 polyamide.…”
Section: The Development Of Multi-strand Techniquesmentioning
confidence: 99%
“…Verdan (1960) managed the adhesion problem by cross pins through the tendon at a distance from the cut and a fine 'arterial' peripheral suture (Figure 1(C)); the sheath at the repair site was excised for 2.5 cm to prevent adhesion. Kleinert et al (1973) used a short criss-cross core suture (essentially a short Bunnell suture) and a peripheral suture, with fine 5-0 and 6-0 sutures, respectively (Figure 1(D)). Kleinert et al (1981) later reported the modified Kessler core suture and used 3-0 braided polyester and 4-0 polyamide.…”
Section: The Development Of Multi-strand Techniquesmentioning
confidence: 99%
“…All the core sutures used 4-0 braided polyblend suture (FiberWire Arthrex, Inc. Naples, FL, USA). A simple continuous epitendinous suture was performed using a 6-0 monofilament polypropylene (Prolene, Ethicon, Somerville, NJ, USA) (Kleinert et al, 1973). The simple running epitendinous throws were approximately 2 mm from the lacerated tendon ends, with approximately 1 mm between each throw.…”
Section: Specimen Preparationmentioning
confidence: 99%
“…The best approach for restoring flexor tendon function after injury has evolved with time. Primary repair with a core and peripheral suture is now standard (Kleinert et al, 1973;Strickland, 1995). Multi-strand core suture techniques are ideal, although contention exists regarding the ideal number of strands Gill et al, 1999;McDonald et al, 2013;Thurman et al, 1998;Viinikainen et al, 2004).…”
Section: Introductionmentioning
confidence: 99%