2015
DOI: 10.1016/j.ultras.2014.12.006
|View full text |Cite
|
Sign up to set email alerts
|

Primary reciprocity-based method for calibration of hydrophone magnitude and phase sensitivity: Complete tests at frequencies from 1 to 7MHz

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2017
2017
2025
2025

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 29 publications
(47 reference statements)
0
5
0
Order By: Relevance
“…Complex sensitivities for the three needle hydrophones were measured using a digital time-delay spectrometry (TDS) system previously described [27, 53]. (There are many methods for measuring sensitivity magnitude but fewer methods for measuring sensitivity phase [5357], with some TDS methods extending to frequencies as high as 40 MHz [27, 56] and a nonlinear method providing phase measurements at harmonic frequencies up to 100 MHz [55] Some methods have shown that common hydrophone measurement systems can be accurately modeled as minimum phase systems [27, 53, 56]. ) A PVDF membrane hydrophone (HMB-200, Onda Corp., Sunnyvale, CA) was used for a reference in substitution experiments.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Complex sensitivities for the three needle hydrophones were measured using a digital time-delay spectrometry (TDS) system previously described [27, 53]. (There are many methods for measuring sensitivity magnitude but fewer methods for measuring sensitivity phase [5357], with some TDS methods extending to frequencies as high as 40 MHz [27, 56] and a nonlinear method providing phase measurements at harmonic frequencies up to 100 MHz [55] Some methods have shown that common hydrophone measurement systems can be accurately modeled as minimum phase systems [27, 53, 56]. ) A PVDF membrane hydrophone (HMB-200, Onda Corp., Sunnyvale, CA) was used for a reference in substitution experiments.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Various techniques have been explored for calibrating hydrophones [6], [18], [21], [26]- [28]. Optical interferometers are capable of measuring broadband and finite amplitude distorted ultrasound fields several megapascals in amplitude.…”
Section: Realizing the Acoustic Pascalmentioning
confidence: 99%
“…Ultrasound has been demonstrated to be useful to cell culture treatment [79], as well. In all cases, a proper evaluation of ultrasonic parameters or transducer characteristics plays an important role, and some basic metrological procedures shall be followed, including uncertainty determination [80][81][82][83].…”
Section: The Futurementioning