2022
DOI: 10.17113/ftb.60.03.22.7505
|View full text |Cite
|
Sign up to set email alerts
|

Primary Metabolite Chromatographic Profiling as a Tool for Chemotaxonomic Classification of Seeds from Berry Fruits

Abstract: Research background. Considering the importance of consumption of berry fruits with proven health-beneficial properties, and difficulties in quality control of products of specific botanical and geographic origin, a fingerprint method was developed, based on advanced data analysis (pattern recognition, classification), in order to relate the variability of nutrients among selected cultivars according to primary metabolites profile. Experimental approach. Forty-five samples of genuine berry fruit cultivars (st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…HMF was detected and quantified at 285 nm using the calibration curve of the HMF standard with a concentration range of 1–15 mg/L. Sugars in honey samples were determined by high‐performance anion‐exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) method with Dionex CarboPac PA100 column as described in Krstić et al [31] …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…HMF was detected and quantified at 285 nm using the calibration curve of the HMF standard with a concentration range of 1–15 mg/L. Sugars in honey samples were determined by high‐performance anion‐exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) method with Dionex CarboPac PA100 column as described in Krstić et al [31] …”
Section: Methodsmentioning
confidence: 99%
“…HMF was detected and quantified at 285 nm using the calibration curve of the HMF standard with a concentration range of 1-15 mg/L. Sugars in honey samples were determined by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) method with Dionex CarboPac PA100 column as described in Krstić et al [31] Preparation of Bee Pollen-Honey Mixtures Bee pollen-honey mixtures were prepared by adding each bee pollen to each honey at 20 % (B1/1-B1/8, S1/ 1-S1/8, L1/1-L1/8) and 30 % (B2/1-B2/8, S2/1-S2/8, L2/1-L2/8). Corresponding amounts of honey and powdered bee pollen were mixed by mechanical stirring until homogenization.…”
Section: Bee-pollen and Honey Samplesmentioning
confidence: 99%