2001
DOI: 10.1111/j.1365-2621.2001.tb16140.x
|View full text |Cite
|
Sign up to set email alerts
|

Prevention of Transient Discoloration of Beef

Abstract: Oxygen absorbent technology in conjunction with controlled atmosphere packaging(CAP) was used to prevent transient discoloration in master-packaged beef steaks. Two types of commercial O 2 scavengers were used in the study. The master packs were stored at 1Ϯ 0.5 ЊC. The steaks from master packs were presented in a display-case for visual evaluation. Reflectance spectra from each steak-surface were obtained to estimate metmyoglobin content. Steaks packaged without O 2 scavengers showed more discoloration, and h… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0
3

Year Published

2007
2007
2015
2015

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(25 citation statements)
references
References 20 publications
0
15
0
3
Order By: Relevance
“…2B). This phenomenon has been described by other authors (Mancini & Hunt, 2005;O'Keeffe & Hood, 1980-1981aTewari et al, 2001). In particular conditions, OxyMb is not converted directly to DeoxyMb, but first undergoes reversible oxidation to a ferric redox state.…”
Section: Color and Myoglobin Formsmentioning
confidence: 70%
See 2 more Smart Citations
“…2B). This phenomenon has been described by other authors (Mancini & Hunt, 2005;O'Keeffe & Hood, 1980-1981aTewari et al, 2001). In particular conditions, OxyMb is not converted directly to DeoxyMb, but first undergoes reversible oxidation to a ferric redox state.…”
Section: Color and Myoglobin Formsmentioning
confidence: 70%
“…At least, four main factors can influence this residue: i) the effectiveness of the MAP equipment in removing air; ii) the permeability of the tray-wrap packaging materials in enabling the oxygen exchanges from the headspace of the tray towards the master bag headspace; iii) the oxygen scavengers absorbing kinetic iv) the oxygen uptake of the muscle itself. In fact, two isolated systems affect the O 2 concentration in the overall package-atmosphere of master bags (Tewari et al, 2001), namely the headspace of the master bag and the headspace of the tray inserted into the master bag itself (i.e. the primary package).…”
Section: Residual O 2 Concentrationmentioning
confidence: 99%
See 1 more Smart Citation
“…As reported by different authors (Tewari, Jayas, Jeremiah, & Holley, 2001;Venturini, ContrerasCastillo, Sarantopoulos, & Villanueva, 2006;Limbo et al, 2013), oxygen scavengers are an essential part of master bag solutions, providing a rapid reduction of the residual oxygen concentration and allowing the establishment of the optimal low oxygen level necessary for the reduction of myoglobin to obtain deoxymyoglobin (DMb). This conversion can occur at extremely low oxygen partial pressures through the reversible formation of metmyoglobin (MMb) , and the rate of absorption of the gas is key to reaching the appropriate gas partial pressure in the shortest time.…”
Section: Storage In Master Bagsmentioning
confidence: 94%
“…2). The longer storage allowed the resolution of the transient discoloration through the reduction of surface pigments and the formation of DMb through the previously mentioned reducing enzyme systems in the meat (Gill, 1991;Tewari et al, 2001).…”
Section: Blooming Kineticsmentioning
confidence: 97%