Pretreatment Patient Specific Quality Assurance and Gamma Index Variation Study in Gantry Dependent EPID Positions for IMRT Prostate Treatments

Abstract: Pretreatment quality assurance (QA) is a major concern in complex radiation therapy treatment plans like intensity modulated radiation therapy (IMRT). Present study considers the variations in gamma index for gantry dependent pretreatment verification and commonly practiced zero gantry angle verifications for ten prostate IMRT plans using two commercial medical linear accelerators (Varian 2300 CD, Varian Clinac iX). Two verification plans (the one with all fields at the actual treatment angles and one with all… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 17 publications
(16 reference statements)
0
2
0
Order By: Relevance
“…[7][8][9] Moreover, linear accelerator (linac) rotation can affect gantry-mounted accessories such as the electronic portal imaging device (EPID), since the EPIDsupporting arm is not mechanically perfect and rigidly attached. With the growing application of EPIDs in preand post-treatment dosimetry verification, [10][11][12][13][14][15] realtime dosimetry verification 16,17 and real-time tumour tracking for intrafraction motion management in modern radiotherapy, [18][19][20] it is essential to characterize and account for the mechanical system imperfections of linacs.…”
Section: Conclusion and Advances In Knowledgementioning
confidence: 99%
“…[7][8][9] Moreover, linear accelerator (linac) rotation can affect gantry-mounted accessories such as the electronic portal imaging device (EPID), since the EPIDsupporting arm is not mechanically perfect and rigidly attached. With the growing application of EPIDs in preand post-treatment dosimetry verification, [10][11][12][13][14][15] realtime dosimetry verification 16,17 and real-time tumour tracking for intrafraction motion management in modern radiotherapy, [18][19][20] it is essential to characterize and account for the mechanical system imperfections of linacs.…”
Section: Conclusion and Advances In Knowledgementioning
confidence: 99%
“…Moreover, linac rotation can affect gantry-mounted accessories such as the electronic portal imaging device (EPID), since the EPID supporting arm is not mechanically perfect and rigidly attached. With the growing application of EPIDs in pretreatment and posttreatment dosimetry verification, 21 26 real-time dosimetry verification, 27 , 28 and real-time tumor tracking for intra-fraction motion management in modern radiotherapy, 29 31 it is essential to characterize and account for the mechanical system imperfections of linacs.…”
Section: Introductionmentioning