2014
DOI: 10.1177/1708538114560455
|View full text |Cite
|
Sign up to set email alerts
|

Pretreatment of synthetic vascular grafts with heparin before implantation, a simple technique to reduce the risk of thrombosis

Abstract: Thrombosis of synthetic grafts commonly used in cardiovascular surgery is a major complication. We examined whether pretreatment of the graft with heparin reduces the risk of early thrombosis. A circuit was assembled to compare two pairs of shunts simultaneously in the same animal. The study shunts were pretreated with heparin. After 2 hours of circulation, clot formation was evaluated by image analysis techniques. The pretreated grafts had fewer blood clots adhered to the surface by direct visual inspection. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 14 publications
0
1
0
Order By: Relevance
“…As showed in Figure 5, all parameters considered for electrospun samples showed no significant difference compared to Dacron control, except for reaction time, which is prolonged on RND and ALN scaffolds. Reaction time represents the time needed for the beginning of the coagulation process, and, while this parameter for electrospun scaffolds still fits the range of physiological values [44], an increased reaction time could imply a decrease of probability of thrombus formation, a common problem in vascular substitution [45,46]. To evaluate the behavior of endothelial cells seeded onto electrospun scaffolds, and therefore scaffolds' cytocompatibility with cells of vascular environment, EA.hy926 viability and morphology were assessed.…”
Section: Resultsmentioning
confidence: 99%
“…As showed in Figure 5, all parameters considered for electrospun samples showed no significant difference compared to Dacron control, except for reaction time, which is prolonged on RND and ALN scaffolds. Reaction time represents the time needed for the beginning of the coagulation process, and, while this parameter for electrospun scaffolds still fits the range of physiological values [44], an increased reaction time could imply a decrease of probability of thrombus formation, a common problem in vascular substitution [45,46]. To evaluate the behavior of endothelial cells seeded onto electrospun scaffolds, and therefore scaffolds' cytocompatibility with cells of vascular environment, EA.hy926 viability and morphology were assessed.…”
Section: Resultsmentioning
confidence: 99%