1999
DOI: 10.1002/(sici)1520-6777(1999)18:3<205::aid-nau7>3.0.co;2-8
|View full text |Cite
|
Sign up to set email alerts
|

Pressure-flow studies: Short-time repeatability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0
1

Year Published

2000
2000
2012
2012

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 11 publications
0
7
0
1
Order By: Relevance
“…In a recent study performed in our clinic, we found a moderate intra-patient reproducibility of PFS [Sonke et al, 1999]. However, better results concerning reproducibility were reported earlier [vd Beek et al, 1992;Madsen et al, 1995;Rosier et al, 1995;Hansen et al, 1997Hansen et al, , 1999. A distinction should be made between reproducibility within one session of two PFS and reproducibility of two PFS performed at different occasions.…”
Section: Introductionmentioning
confidence: 52%
See 1 more Smart Citation
“…In a recent study performed in our clinic, we found a moderate intra-patient reproducibility of PFS [Sonke et al, 1999]. However, better results concerning reproducibility were reported earlier [vd Beek et al, 1992;Madsen et al, 1995;Rosier et al, 1995;Hansen et al, 1997Hansen et al, , 1999. A distinction should be made between reproducibility within one session of two PFS and reproducibility of two PFS performed at different occasions.…”
Section: Introductionmentioning
confidence: 52%
“…Hansen et al [1999] investigated the short-time reproducibility of PFS. In 20 patients they performed four PFS in two sessions.…”
Section: Discussionmentioning
confidence: 99%
“…In the Broekhuis et al14 series, the post‐miction residue was reproducible with a CCI of 0.80. In conventional urodynamic studies in prostatic syndrome patients, Hansen et al24 and Tammela et al25 found that this parameter is reproducible, although other parameters of the micturition phase were not, such as the pressure of the detrusor with maximal flow or the parameters of ureteral resistance and detrusor contractility.…”
Section: Discussionmentioning
confidence: 99%
“…Poor reproducibility of pressure‐flow parameters in conventional urodynamic study, such as Q max , P det. Q max , and voided volume, on immediate re‐testing and after short‐term follow‐up has been reported in males and females 4,18 . Considerable variability is noted when pressure/flow studies are repeated on the same day, with 25–39% of subjects having a urodynamic diagnosis of obstruction change to equivocal or unobstructed in the second study 4,18,19 .…”
Section: Discussionmentioning
confidence: 99%
“…Q max , and voided volume, on immediate re‐testing and after short‐term follow‐up has been reported in males and females 4,18 . Considerable variability is noted when pressure/flow studies are repeated on the same day, with 25–39% of subjects having a urodynamic diagnosis of obstruction change to equivocal or unobstructed in the second study 4,18,19 . Kortmann et al 20 reported that the reproducibility of manual analysis of urodynamic studies in men with lower urinary tract symptoms is only moderate due to considerable intra‐ and inter‐investigator variation.…”
Section: Discussionmentioning
confidence: 99%