2017
DOI: 10.1016/j.ijheatfluidflow.2017.02.008
|View full text |Cite
|
Sign up to set email alerts
|

Pressure drop measurements for woven metal mesh screens used in electrical safety switchgears

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

2
22
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(24 citation statements)
references
References 31 publications
2
22
0
Order By: Relevance
“…Moreover, the drag force model for RPBs in their work is derived from the single‐phase model proposed by Kołodziej 40 . This single‐phase model has been modified and improved by Kołodziej et al 43 and Bussière et al 44 Therefore, to further improve the simulation accuracy of RPBs, it is necessary to test and compare the accuracy of the new multiphase drag force models for RPBs derived from the modified single‐phase drag force models.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the drag force model for RPBs in their work is derived from the single‐phase model proposed by Kołodziej 40 . This single‐phase model has been modified and improved by Kołodziej et al 43 and Bussière et al 44 Therefore, to further improve the simulation accuracy of RPBs, it is necessary to test and compare the accuracy of the new multiphase drag force models for RPBs derived from the modified single‐phase drag force models.…”
Section: Introductionmentioning
confidence: 99%
“…Sudden pressure reduction and changes in flow direction inside the intake screens may lead to the formation of vortices in the suction pipes. Only a few researchers have conducted numerical simulations in order to solve the flow field and determine the flow pattern within and around the screen [20][21][22][23][24]. Unlike the previous researchers that have obtained results from the studies carried out on the friction factor and the pressure drop in the screen, the present study in a different manner surveys the vortex formation, flow patterns and flow uniformity inside a metal screen of the water intake system of a pumping station under tidal conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Setekleiv and Svendsen [8] measured the dry pressure drop for 8 wire mesh pads with three fluid systems: one low pressure system using air and two high pressure systems using nitrogen and natural gas. Bussière et al [9] experimentally investigated the correlation between the pressure loss (friction factor) and velocity (Reynolds number) on the system of woven metal screens being the friction inducer and water being the working fluid. These screens are usually used as filters in LV circuit breakers.…”
Section: Introductionmentioning
confidence: 99%