2007
DOI: 10.1080/00016480500488917
|View full text |Cite
|
Sign up to set email alerts
|

Preservation of low frequency hearing in partial deafness cochlear implantation (PDCI) using the round window surgical approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
148
0
4

Year Published

2011
2011
2020
2020

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 180 publications
(158 citation statements)
references
References 15 publications
6
148
0
4
Order By: Relevance
“…It involved inclusion of three principal criteria: a. Application of Skarżyński's surgical method of six steps [13].…”
Section: Resultsmentioning
confidence: 99%
“…It involved inclusion of three principal criteria: a. Application of Skarżyński's surgical method of six steps [13].…”
Section: Resultsmentioning
confidence: 99%
“…The authors demonstrated that preservation of hearing thresholds was more successful when the soft surgery technique was used with median changes in average hearing thresholds between 250-500Hz measured at 40dB for the entire group and 23dB for the soft surgery group. Success in hearing preservation has also been reported using partial insertion of other electrode arrays, including the MED-EL C40+ implant (Gstoettner et al, 2004;Skarzynski et al, 2007). However delayed loss of residual hearing has been reported in some instances even when an atraumatic surgical technique is used (Fraysse et al, 2006;Gstoettner et al, 2006).…”
Section: Effect Of Residual Hearing Preservation On Music Perception mentioning
confidence: 97%
“…Gstoettner et al 57 reported on 18 of 21 cases (86%) in which a full or partial preservation was achieved. Skarzynski et al 54 reported on 9 of 10 cases (90%) of hearing preservation. With regard to long-term preservation, Gstoettner et al 59 presented data on 23 subjects and concluded that long-term preservation of ipsilateral hearing after CI implantation can be achieved in about 70% of cases.…”
Section: Hearing Preservationmentioning
confidence: 99%
“…Most authors therefore recommend a 360°insertion with insertion depths of about 18 to 20 mm for a hearingpreserving CI implantation. 50,52,54,56,57 To facilitate hearing preservation in CI surgery for EAS, MED-EL has developed the FLEX eas electrode. The FLEX eas electrode is a medium-length electrode (20.9 mm contact extent) with a highly flexible tip suitable for both cochleostomy and round window insertions.…”
Section: Hearing Preservationmentioning