Present Status of YU-AMS System

Abstract: A new compact accelerator mass spectrometry (AMS) system has been installed in the Kaminoyama Research Institute at Yamagata University (YU). The AMS system is based on a 0.5MV Pelletron accelerator developed by the National Electrostatics Corporation. An automated acid-alkali-acid (AAA) treatment system and an automated graphitization line were also installed in the same facility for sample preparation. Performance tests of the YU-AMS system were carried out by measuring the C-series standard samples (C1–C8) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 16 publications
1
14
0
Order By: Relevance
“…Fine The sample preparation processing, including an oxidation (cellulose → CO 2 ), a CO 2 purification (process of removing impurities using cold traps), the graphitization (CO 2 → C: hydrogen reduction with Fe catalyst), and the AMS measurement were conducted at Yamagata University. The AMS system in Yamagata University (YU-AMS) is based on a conventional AMS instrument (Tokanai et al 2013). The 14 C content in six new NIST standards and two blank samples were also measured with the unknown samples.…”
Section: Methodsmentioning
confidence: 99%
“…Fine The sample preparation processing, including an oxidation (cellulose → CO 2 ), a CO 2 purification (process of removing impurities using cold traps), the graphitization (CO 2 → C: hydrogen reduction with Fe catalyst), and the AMS measurement were conducted at Yamagata University. The AMS system in Yamagata University (YU-AMS) is based on a conventional AMS instrument (Tokanai et al 2013). The 14 C content in six new NIST standards and two blank samples were also measured with the unknown samples.…”
Section: Methodsmentioning
confidence: 99%
“…The weight ratios of the graphite to 1 mg of iron powder were kept between 0.6 and 1.2. Measurements of 14 C in the graphite samples were carried out using a 500 KV tandem accelerator at the Yamagata University (YU-AMS) 29 . The 14 C concentrations for the graphite samples were obtained using the measured values of the 14 C/ 12 C ratio for samples and 4990 C oxalic acid, which is a standard sample.…”
Section: Pretreatments and Measurementsmentioning
confidence: 99%
“…This new multipurpose tandem accelerator will see various uses, including, AMS, IBA, ion irradiation, and nuclear physics. The new system will start routine multi-nuclide AMS measurements of 10 Be, 14 Fig. 3.…”
Section: Discussionmentioning
confidence: 99%
“…14 C-AMS using a CO 2 gas-ion source is intended to improve lowbackground and high-repeatability measurements. We also installed an automatic sample-preparation system [14] with an elemental analyzer and a gas chromatograph for 14 C samples.…”
Section: Ams Performancementioning
confidence: 99%
See 1 more Smart Citation