2008
DOI: 10.1109/tps.2008.917514
|View full text |Cite
|
Sign up to set email alerts
|

Present Status of the New Multifrequency ECRH System for ASDEX Upgrade

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 13 publications
0
18
0
Order By: Relevance
“…In the present work the full capabilities of the CTS system have not yet been fully exploited: the signal-to-noise ratio has been increased at the expense of time resolution. In future experiments it may be possible to inject higher gyrotron powers [52] which may improve the signal-to-noise ratio and thus enable us to increase the time resolution. This may allow detailed studies of plasma dynamics on millisecond time scales by CTS -the results of which may be interesting to compare with numerical simulations.…”
Section: Discussionmentioning
confidence: 99%
“…In the present work the full capabilities of the CTS system have not yet been fully exploited: the signal-to-noise ratio has been increased at the expense of time resolution. In future experiments it may be possible to inject higher gyrotron powers [52] which may improve the signal-to-noise ratio and thus enable us to increase the time resolution. This may allow detailed studies of plasma dynamics on millisecond time scales by CTS -the results of which may be interesting to compare with numerical simulations.…”
Section: Discussionmentioning
confidence: 99%
“…2 transmission line described in detail in Ref. 9. The ECRH antennae are steerable enabling the possibility of different scattering geometries.…”
Section: The Cts At Asdex Upgrade Hardwarementioning
confidence: 99%
“…7,8 The microwave based fast CTS diagnostic installed on AS-DEX Upgrade ͑CTS-AUG͒ uses millimeter waves generated by the newly installed 1 MW dual frequency gyrotron as probing radiation at 105 GHz. 9 This paper will include a brief overview of the hardware in Sec. II and the diagnostic capability in Sec.…”
Section: Introductionmentioning
confidence: 99%
“…Accompanied by the magnetic field of the reactors, the ECRH frequency of ITER and JT-60SA is 170 GHz [2,3] and 110 / 137 GHz [4,5], respectively. Other than ITER and JT-60SA, many devices employ the ECRH system and have individual gyrotron frequency tied to long term R&D. Additionally, a dual frequency gyrotron have been studied for a future advanced ECRH system [6,7]. On the other hand, the frequency range is limited due to the gyrotron market for industries.…”
Section: Introductionmentioning
confidence: 99%