Preparation of Spectrographic Standards of Low Boron Content for Determination of Boron in Iron

Abstract: Spectrographic determination of boron in steel has been hindered by the lack of reliable standards in the low boron range.By using vacuum melting techniques and careful ingot processing, precise boron standards can be made which contain as little as 1 p.p.m. of boron.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

1957
1957
1967
1967

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 1 publication
0
1
0
Order By: Relevance
“…Spectrographic reference steels for the boron concentration range from 0.0001 to 0.0006% were prepared by vacuum melting high purity iron with addition of the proper quantities of National Bureau of Standards' No. 830 spectrographic standard (149).…”
Section: • Analytical Chemistrymentioning
confidence: 99%
“…Spectrographic reference steels for the boron concentration range from 0.0001 to 0.0006% were prepared by vacuum melting high purity iron with addition of the proper quantities of National Bureau of Standards' No. 830 spectrographic standard (149).…”
Section: • Analytical Chemistrymentioning
confidence: 99%