1979
DOI: 10.1111/j.1399-3011.1979.tb01955.x
|View full text |Cite
|
Sign up to set email alerts
|

PREPARATION OF RACEMIC 2r‐CARBOXY‐TRANS, TRANS‐3, 4‐DIDEUTERO‐PYRROLIDINE (DL‐TRANS, TRANS‐3, 4‐DIDEUTERO‐PROLINE) AND UNAMBIGUOUS ASSIGNMENT OF PROTONS IN THE 1H N.M.R. SPECTRUM OF PROLINE

Abstract: Racemic trans, trans-3.4-dideutero proline has been prepared by catalytic deuteration of 3-pyrroline-2-carboxylic acid, The stereospecificity o f the reduction (i.e. trans to the carboxylic group) was ascertained after transformation of the dideutero compound into the diketopiperazide c/Pro, Aibl, for which unambiguous proton assignments in the ' H n.m.r. spectrum had been obtained previously. The identification of the configuration of the dideuteroproline allows for the affirmation of the correctness o f prot… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

1981
1981
2017
2017

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 17 publications
0
4
0
Order By: Relevance
“…Proton NMR Spectral Analysis . The published NMR data for l -proline in water reveal some inconsistencies in the reported J -couplings, especially in the values of the vicinal 3 J -couplings. ,2b, The reason for such inconsistency is the complexity of the spectrum characteristic for a strongly coupled spin system 10a. None of the previous analyses are complete, as no iterative fittings to experimental spectra, either by LAOCN3 10b or full line shape 10c,d calculations, were reported. 2b, These incomplete analyses of strongly coupled 1 H spectra were likely to lead to inaccurate J -couplings, as confirmed by our results presented below.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Proton NMR Spectral Analysis . The published NMR data for l -proline in water reveal some inconsistencies in the reported J -couplings, especially in the values of the vicinal 3 J -couplings. ,2b, The reason for such inconsistency is the complexity of the spectrum characteristic for a strongly coupled spin system 10a. None of the previous analyses are complete, as no iterative fittings to experimental spectra, either by LAOCN3 10b or full line shape 10c,d calculations, were reported. 2b, These incomplete analyses of strongly coupled 1 H spectra were likely to lead to inaccurate J -couplings, as confirmed by our results presented below.…”
Section: Resultsmentioning
confidence: 99%
“…d Values reported at pD = 7.4. The spectral parameters were determined by eye comparison of the experimental (250 MHz) and the calculated spectra 2b…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations