2022
DOI: 10.1039/d2ra04968f
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of chitosan-coated polystyrene microspheres for the analysis of trace Pb(ii) ions in salt by GF-AAS assisted with solid-phase extraction

Abstract: Chitosan-coated polystyrene solid-phase extraction fillers.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 38 publications
(38 reference statements)
0
3
0
Order By: Relevance
“…For the ETAAS determination of Pb in salt, Ding et al retained both sodium and Pb on a column of chitosan-coated polystyrene microspheres. 65 A volume of 5 mL of sample containing not more than 0.3% (m/v) of salt was left in the column overnight and the retained sodium eluted with 10 mL of 0.1 mol L −1 HCl, followed by the elution of Pb with 10 mL of 2 mmol L −1 Na 2 EDTA. Other than reporting a LOD of 0.087 μg L −1 and some column recoveries, the researchers provided almost no information about the application of the method to the analysis of real samples.…”
Section: Sample Collection and Preparationmentioning
confidence: 99%
“…For the ETAAS determination of Pb in salt, Ding et al retained both sodium and Pb on a column of chitosan-coated polystyrene microspheres. 65 A volume of 5 mL of sample containing not more than 0.3% (m/v) of salt was left in the column overnight and the retained sodium eluted with 10 mL of 0.1 mol L −1 HCl, followed by the elution of Pb with 10 mL of 2 mmol L −1 Na 2 EDTA. Other than reporting a LOD of 0.087 μg L −1 and some column recoveries, the researchers provided almost no information about the application of the method to the analysis of real samples.…”
Section: Sample Collection and Preparationmentioning
confidence: 99%
“…Fourier transform infrared spectroscopy (FTIR) is an effective method for analyzing the functional moieties present in the products. Additionally, peaks at 2930 cm −1 and 2862 cm −1 were attributed to alkyl C-H stretching vibrations [43]. Peak at 1376 cm −1 indicated C-H out-of-phase bending vibrations of the aliphatic chain.…”
Section: Ftirmentioning
confidence: 99%
“…The other paper to analyse salt was presented by Ding et al who used solid phase extraction to obtain a matrix removal and preconcentration stage prior to GFAAS detection of Pb . 134 Polystyrene microspheres were used as carriers for a chitosan coated polystyrene. The material was synthesised by sulfonating with sulfonyl chloride, coating with chitosan and then cross-linking with glutaraldehyde.…”
Section: Inorganic Chemicals and Materialsmentioning
confidence: 99%