2020
DOI: 10.1080/10667857.2020.1728059
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and performance of a solid-state thin-film Ag/AgCl quasi-reference electrode modified by chitosan-graphene

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 30 publications
0
5
0
Order By: Relevance
“…28 The stability of reference electrode.-In this section, electrodes with three different modification materials (Nafion, PDA and Nafion-PDA) and an Ag/AgCl electrode without modification, which was used as a comparison. The four electrodes were dipped in pH buffer solutions with pH 4.00, 6.86 and 9.18 for 1500 s 22,23 and the potential was recorded at 1 Hz.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…28 The stability of reference electrode.-In this section, electrodes with three different modification materials (Nafion, PDA and Nafion-PDA) and an Ag/AgCl electrode without modification, which was used as a comparison. The four electrodes were dipped in pH buffer solutions with pH 4.00, 6.86 and 9.18 for 1500 s 22,23 and the potential was recorded at 1 Hz.…”
Section: Resultsmentioning
confidence: 99%
“…The chlorinated electrodes were immersed in a saturated silver chloride solution for 4 h in dark environment to improve the stability of the reference potential. 23 Nafion was used as one of the 3 types of modification materials in this study. 15 μl of the 0.5 wt% Nafion solution, diluted by 5 wt% Nafion solution with anhydrous ethanol, was pipetted on the surface of the reference electrode.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This electrode captures the potential difference present in the seawater, transmuting it into an electrical signal which is subsequently subjected to post-processing and recording procedures. In comparison with alternative electrode types, the Ag/AgCl electrode presents distinct advantages such as heightened stability, facile preparation, and an extensive potential range [2][3][4] . Consequently, this electrode finds widespread utilization within the realm of oceanic electric field measurement.…”
Section: Introductionmentioning
confidence: 99%
“…15,16 Bare Ag/AgCl electrodes were proposed as quasi-REs in some applications as an alternative option to conventional REs. 13 However, their core Ag/AgCl reference elements are exposed, so they become unbalanced and quickly degrade. In the sense of true reference electrodes, some researchers went a little out of the traditional route of Ag/AgCl with a salt bridge and exploited the potential of redox couples or ionic liquids.…”
Section: Introductionmentioning
confidence: 99%