2011
DOI: 10.1515/epoly.2011.11.1.8
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and characterization of poly(acryl amide-coacrylic acid)/nay and Clinoptilolite nanocomposites with improved methylene blue dye removal behavior from aqueous solution

Abstract: Abstract:The nanocomposites of poly(acryl amide-co-acrylic acid) with NaY and Clinoptilolite were prepared using ammonium persulfate as an initiator and N,N′-methylene bis acryl amide as the cross-linker. The morphology was characterized by SEM and the structure of nanocomposite materials was studied with XRD and FT-IR that showed the interaction between porous materials and poly(AAm-coAAc). Thermo gravimetric analyzer (TGA) curve shows that all the chain-extended poly(AAm-co-AAc) are stable up to 250 °C and m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 25 publications
(33 reference statements)
0
8
0
Order By: Relevance
“…Where 𝐶 0 and 𝐶 are the initial and equilibrium concentration of the MB dye solution, respectively [23][24].…”
Section: Adsorption Of Methylene Bluementioning
confidence: 99%
See 1 more Smart Citation
“…Where 𝐶 0 and 𝐶 are the initial and equilibrium concentration of the MB dye solution, respectively [23][24].…”
Section: Adsorption Of Methylene Bluementioning
confidence: 99%
“…It showed that the more the amorphous in the matrix more will be the swelling. It was clear that the regular crystal structure of clay was partly destroyed and the clay platelets were intercalated and dispersed in the nanocomposite hydrogel matrix [23,24,28].…”
Section: Xrd Studiesmentioning
confidence: 99%
“…The first step of degradation occurs in the range of 30-200 ∘ C where a weight loss of 14.6% is observed. This could be due to loss of entrapped water molecules and volatile impurities along with degradation of soft segment of Pec-g-PAAm [15]. The weight loss in this step may be assigned to the loss of ppm Pec-g-PAAm · mpr ppm Pec-g-PAAm · mpr ppm Pec-g-PAAm · mpr ppm Pec-g-PAAm · mpr ppm Pec-g-PAAm · mpr 500 ppm Pec-g-PAAm · mpr Figure 9 grafted links between the pectin and polyacrylamide.…”
Section: Thermogravimetric Analysismentioning
confidence: 99%
“…Different factors such as stability of the composite and strength of bond between the drug and the composite can affect on the rate of release. The hydrophilic groups such as hydroxyl on the PEG and porous material got hydrolyzed on the buffer solutions and it seems like the hydrogen bond between metronidazole and the composite is weaker than the porous material alone and the rate of hydrolyzed increased [ 7 , 25 , 26 ].…”
Section: Drug Release By Peg/porous Materialsmentioning
confidence: 99%