2021
DOI: 10.1016/j.ijbiomac.2020.11.078
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and characterization of nanostarch-based green hard capsules reinforced by cellulose nanocrystals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 26 publications
1
7
0
Order By: Relevance
“…20,21 Due to the incorporation of CNCs, the absorption wavelength related to the stretching vibration of –OH peak of CNC/RC slightly shifted to a lower wavelength (from 3336 cm −1 to 3329 cm −1 ), indicating an increase in hydrogen bonds between hydroxyl groups of RC films and CNCs. 22 As expected, other differences introduced by the addition of CNCs were not obvious, from the low CNC contents deposited on the surface of RC films. Fig.…”
Section: Structure Of Cnc/rc Filmssupporting
confidence: 63%
“…20,21 Due to the incorporation of CNCs, the absorption wavelength related to the stretching vibration of –OH peak of CNC/RC slightly shifted to a lower wavelength (from 3336 cm −1 to 3329 cm −1 ), indicating an increase in hydrogen bonds between hydroxyl groups of RC films and CNCs. 22 As expected, other differences introduced by the addition of CNCs were not obvious, from the low CNC contents deposited on the surface of RC films. Fig.…”
Section: Structure Of Cnc/rc Filmssupporting
confidence: 63%
“…All films exhibited a broad peak at 3100−3500 cm −1 attributed to O−H stretching (Figure S1c). 49,50 The neat CNC film presented peaks at 3325 and 3280 cm −1 responding to intra-and intermolecular hydrogen bonding, respectively. 51 The FT-IR spectra of the composite films had peaks similar to those of the neat CNC films, which confirmed that the proximity of the glucan does not destroy the network of intra-and intermolecular hydrogen bonding of CNC particles, and the preservation of hydrogen bonding is conducive to close packing of the glucan backbone with CNCs.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…The loss on drying test of capsules was conducted according to (Chen et al ., 2021) with slight modification. Capsule sample with approximate weight of 1 g was placed in moisture analyser (model IR‐30, Denver Instruments, Bohemia, NY).…”
Section: Methodsmentioning
confidence: 99%