1988
DOI: 10.1080/01411598808206814
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and characterization of manganese and cobalt based semiconducting ceramics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
20
0

Year Published

1993
1993
2018
2018

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 16 publications
(22 citation statements)
references
References 2 publications
2
20
0
Order By: Relevance
“…). The substitution of Mn 3+ ions by Co 2+ and Mn 4+ ions according to the transformation schematic 2Mn 3+ oh → Co 2+ oh + Mn 4+ oh , with the creation of Mn 3+ /Mn 4+ couples, was also considered in the past , but the Co 2+ [Co 2+ y Mn 3+ 2−2 y Mn 4+ y ]O 2− 4 model, with 0 < y < 1 and y = x − 1, gives a y value of 1. Therefore, MnCo 2 O 4 should be an insulator, in contradiction with the experiments that showed a maximum of conductivity around this composition (see Fig.…”
Section: Discussionmentioning
confidence: 99%
“…). The substitution of Mn 3+ ions by Co 2+ and Mn 4+ ions according to the transformation schematic 2Mn 3+ oh → Co 2+ oh + Mn 4+ oh , with the creation of Mn 3+ /Mn 4+ couples, was also considered in the past , but the Co 2+ [Co 2+ y Mn 3+ 2−2 y Mn 4+ y ]O 2− 4 model, with 0 < y < 1 and y = x − 1, gives a y value of 1. Therefore, MnCo 2 O 4 should be an insulator, in contradiction with the experiments that showed a maximum of conductivity around this composition (see Fig.…”
Section: Discussionmentioning
confidence: 99%
“…The medium resolution and high intensity powder diffractometer Polaris has four detector banks that measure simultaneously: the backscattering and low angle banks using 3 He gas tube detectors, and 90 and very low angle detector banks using ZnS scintillators. Only the time-of-flight data collected from the 58 backscattering detectors, that offer the best resolution over a large range of d-spacings (0.2-3.2 ), and obtained after 30 min-2 h depending on the amount of sample, were used for structural determination.…”
Section: Characterizationmentioning
confidence: 99%
“…Neutron diffraction patterns were also collected at room temperature with the high resolution 2D neutron detector available at the ILL. The Super D2B instrument has a 135 take-off angle and 128 3 He detectors. Powder diffraction patterns were recorded using a 1.5941 Å wavelength in the 10-145 2q domain with a 0.05 step and nine scans of 200,000 Â 1,2 or 4 counts.…”
Section: Characterizationmentioning
confidence: 99%
See 1 more Smart Citation
“…Very few studies [34][35][36][37][38][39][40][41] had been performed on the Mn-Co-O system before the works conducted in our laboratory. They have involved more detailed works on films and powders than on ceramics.…”
Section: Introductionmentioning
confidence: 99%