2021
DOI: 10.1016/j.microc.2021.106179
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and application of aptamer-functionalized sorbent for the analysis of ultra-trace aflatoxin M1 and analogues in milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 36 publications
0
9
0
Order By: Relevance
“…After optimizing the concentrations of the cations in the solution, the supporting electrolyte, Tris/ HCl 50 mmol L À 1 , MgCl 2 10 mmol L À 1 , and NaCl 10 mmol L À 1 , was defined for further studies. An optimal concentration of MgCl 2 10 mmol L À 1 in the solution medium for efficient binding of aptamer with aflatoxin M1 has been reported previously [38].…”
Section: Effect Of Support Electrolyte Salt Concentrationmentioning
confidence: 88%
“…After optimizing the concentrations of the cations in the solution, the supporting electrolyte, Tris/ HCl 50 mmol L À 1 , MgCl 2 10 mmol L À 1 , and NaCl 10 mmol L À 1 , was defined for further studies. An optimal concentration of MgCl 2 10 mmol L À 1 in the solution medium for efficient binding of aptamer with aflatoxin M1 has been reported previously [38].…”
Section: Effect Of Support Electrolyte Salt Concentrationmentioning
confidence: 88%
“…With the emergence of new technologies and novel materials, sample pretreatment methods are also developing. Table S2 [ 11 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , …”
Section: Sample Pretreatment Methodsmentioning
confidence: 99%
“…Recently, based on the specific recognition ability of “chemical antibody”, a new type of SPE adsorbent was developed by using aptamer modified carrier surface as functional monomer, which has advantages of specificity, accuracy, and repeatability for enriching ultra-trace targets. Zhang et al [ 70 ] prepared and applied an M1-aptamer-functionalized sorbent for the adsorption of ultra-trace AFM1 and analogues in milk samples, as shown in Figure 2 A. During the extraction process, the M1-aptamer on the surface of the carboxyl microspheres were completely modified via N-(3-dimethylaminopropyl)-N’-ethylcarbodiimide hydrochloride (EDC)/NHs amide formation.…”
Section: Sample Pretreatment Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…AFM1 can be found in commercially available milk and is generally considered as one of the most serious problems for food safety [ 31 ]. Therefore, its concentration in milk is strictly regulated and the maximum permissible levels of AFM1 in milk and dairy products are set at 0.05 μg kg −1 in the European Union [ 232 ]. An impedimetric aptasensor for the determination of AFM1 in milk, employing the aptamer immobilization at a carboxyphenyl layer grafted by diazonium chemistry onto the surfaces of SPCEs, was developed by Istamboulié et al [ 74 ].…”
Section: Electrochemical Aptasensors Developed Using Aryldiazonium Chemistry For Food Safety Monitoring Applicationsmentioning
confidence: 99%