1998
DOI: 10.1007/s002590050311
|View full text |Cite
|
Sign up to set email alerts
|

Preoperative evaluation of hepatic functional reserve following hepatectomy by technetium-99m galactosyl human serum albumin liver scintigraphy and computed tomography

Abstract: It is extremely important to have a good grasp of the acceptable limit of hepatectomy before operation because postoperative liver failure can take a fatal course; however, baseline data on the limit of hepatectomy have not been clearly defined. We therefore evaluated and compared the predicted remnant liver function obtained by computed tomography(CT) and technetium-99m diethylenetriamine penta-acetic acid-galactosyl human serum albumin (99mTc-GSA) liver scintigraphy in order to obtain precise data regarding … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
73
0

Year Published

2001
2001
2018
2018

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(75 citation statements)
references
References 7 publications
1
73
0
Order By: Relevance
“…The present study applied the reliable liver function markers from 99m Tc-GSA liver scintigraphy, ICGR15, and serum HA level, along with conventional parameters [12,13,16,17]. These noninvasive tests can be routinely performed before hepatectomy.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The present study applied the reliable liver function markers from 99m Tc-GSA liver scintigraphy, ICGR15, and serum HA level, along with conventional parameters [12,13,16,17]. These noninvasive tests can be routinely performed before hepatectomy.…”
Section: Discussionmentioning
confidence: 99%
“…The present study examined relationships between reliable parameters of functional liver reserve such as conventional liver function tests, the indocyanine green (ICG) clearance test [11], serum hyaluronic acid (HA) level [12], and 99m Tc-galactosyl human serum albumin liver scintigraphy ( 99m Tc-GSA scintigraphy) [13] in 93 patients with various liver diseases in whom PP was directly measured. Furthermore, we attempted to derive a comprehensive analytical formula by multivariate analysis to predict PP and then compared predictive PP and true PP.…”
Section: Introductionmentioning
confidence: 99%
“…The accuracy of determining the flow Doppler by IOUS is high (4,5). The flow Doppler's ultrasonographic parameters reflect the dynamics of the hepatic inflow and outflow, which may be associated with both the PP and the background liver status [13,14]. To the best of our knowledge, no indirect prediction of PP using ultrasonographic parameters has yet been reported.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, other reliable functional parameters were needed. Recently, novel tests of FLR, such as serum HA level (13 -15), GSA scintigraphy (16), and interleukin levels (17), have been used to evaluate post-surgical complications. Furthermore, the correlation of LHL15 and HH15 to ICGR15 using a linear regression model and the analysis of individual liver segments by dynamic SPECT are easy and convenient methods for predicting hepatic functional reserve by GSA scintigraphy (18)(19)(20)(21).…”
Section: Introductionmentioning
confidence: 99%