Preliminary testing of the internal gear pump with modifications of the sickle insert

Abstract: This paper presents the modifications that have been made to the sickle insert of the gear pump with internal gearing. This procedure allowed the obtainment of radial compensation. The test stand to plot the characteristics of the pump before, as well as after the first and second modification is discussed. The results of the measurements from the tests conducted are presented. The results obtained confirmed the achievement of radial compensation by cutting the appropriate channel in the sickle insert. As a re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…The basic and main component in a hydrostatic drive system is the positive displacement pump. It is the component in the system where the greatest pressure increase occurs 1 5 . The second important component in the system is the rotary hydraulic motor.…”
Section: Introductionmentioning
confidence: 99%
“…The basic and main component in a hydrostatic drive system is the positive displacement pump. It is the component in the system where the greatest pressure increase occurs 1 5 . The second important component in the system is the rotary hydraulic motor.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the growing share of plastics in the production of hydraulic elements of drive systems [24,25] and the use of new light and high-strength composite materials [26], a modification of the sickle insert was performed by use of plastic with low processing costs. The diagram of the hydraulic system used during the measurements is presented below [27,28] -Fig. 8.…”
Section: Preliminary Test Results For An Internal Gear Pump With Modification Of the Sickle Insertmentioning
confidence: 99%
“…1 -tested gear pump, 2 -tachometer, 3 -torque meter, 4 -electric motor, 5 -control cabinet, 6 -pressure transducer, 7 -throttle valve, 8 -, 9 -cooler, 10safety valve, 11-pressure transducer, 12 -thermometer, 13 -throttle valve on the discharge line of the feed pump, 14 -safety valve on the discharge line of the feed pump, 15 -feed pump, 16 -electric motor driving the feed pump, 17 -control cabinet of the electric motor driving the feed pump. [27,28] To ensure a constant value of the suction pressure of the main pump, a feed pump was installed. The measurements were taken after the test run of the hydraulic system and correctness check of the measurement devices' indications.…”
Section: Preliminary Test Results For An Internal Gear Pump With Modification Of the Sickle Insertmentioning
confidence: 99%