2015
DOI: 10.1088/2057-1976/1/1/015202
|View full text |Cite
|
Sign up to set email alerts
|

Preliminary performance characterization of DbPET2.1, a PET scanner dedicated to the imaging of the breast and extremities

Abstract: The combined effort of several laboratories at our institution resulted in the building of the first high resolution PET/CT prototype dedicated to imaging the body extremities. Ongoing clinical trials for breast cancer diagnosis and assessment of response to treatment underlined the need for a second generation prototype with improved electronics and spatial resolution. A preliminary version has been assembled and fully characterized. In this work we present further improvements in the detector performance as … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…Dynamic PET data collection was not feasible in our system because of its step-andshoot acquisition protocol. This limitation has been addressed in a next-generation system, 42 where investigators could optionally employ a population-based arterial input function 45 or arterial blood sampling. Kinetic parameters thus derived could reveal new knowledge about RA or PsA pathogenesis.…”
Section: Fluorine-18 Fludeoxyglucose Uptake For the First Carpometacamentioning
confidence: 99%
“…Dynamic PET data collection was not feasible in our system because of its step-andshoot acquisition protocol. This limitation has been addressed in a next-generation system, 42 where investigators could optionally employ a population-based arterial input function 45 or arterial blood sampling. Kinetic parameters thus derived could reveal new knowledge about RA or PsA pathogenesis.…”
Section: Fluorine-18 Fludeoxyglucose Uptake For the First Carpometacamentioning
confidence: 99%
“…https://doi.org/10.1371/journal.pone.0236929.g010 In this paper, the skin conductivity proposed by Gabriel's model is used as it is. However, recently, a skin conductivity model has been proposed by De Santis et al [40].…”
Section: Plos Onementioning
confidence: 99%
“…Various groups have developed stand-alone, human breast computed tomography (BCT) systems [32][33][34] (beyond labbased systems that can only image phantoms or specimens 35,36 ), as well as dual-modality systems 26,37 for dedicated breast imaging, only capable of traversing simple circular orbits; for one system, the PET subsystem is capable of helical acquisitions. 38 Software-based suppression of cone beam artifacts has been investigated, but the underlying acquired data remain incompletely sampled, therefore necessitating more accurate data acquisition. To overcome cone beam sampling artifacts in CT and provide better sampling close to the chest wall, our group previously developed independent CT and single-photon emission computed tomography (SPECT) subsystems capable of fully 3-D motions, allowing complex acquisition trajectories [39][40][41] (so-called generation 1).…”
Section: Introductionmentioning
confidence: 99%