Preliminary evaluation of near-infrared vein visualization technology in the screening of palatal blood vessels

Abstract: BackgroundAvoidance from palatal blood vessel rupture is a major concern during the palatal soft tissue graft surgery. There is no defined chair-side and case-specific palatal blood vessel detection approach to facilitate the harvesting process. The objective of this pilot study is to assess the feasibility of a near-infrared vein visualization system in the screening process of palatal blood vessels.Material and MethodsAn extraoral vein visualization device (AccuVein AV400) was applied to a total of 304 hemi-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…Several approaches have been proposed for detecting blood vessels; their comparison is summarized in Table 1 . The vein visualization device [7] is generally used for screening the skin’s surface. The device emits near-infrared light (wavelength: 785 nm) and receives the light reflected from the skin’s surface.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several approaches have been proposed for detecting blood vessels; their comparison is summarized in Table 1 . The vein visualization device [7] is generally used for screening the skin’s surface. The device emits near-infrared light (wavelength: 785 nm) and receives the light reflected from the skin’s surface.…”
Section: Discussionmentioning
confidence: 99%
“…To improve the quality of color Doppler images, the needle must be inserted into the human body to vibrate the local tissue. Recently, the near-infrared vein visualization device was developed for real-time visualization of superficial vessels under the skin [6] [8] ; near-infrared light (wavelength: ~785 nm) is used to penetrate the skin and blood vessels and is partially absorbed at avascular locations but not at vascular locations. Using the difference in absorption between the vascular and avascular locations, the device determines the location of blood vessels.…”
Section: Introductionmentioning
confidence: 99%
“…Medical visualization technology is a three-dimensional model. It can spontaneously perform quantitative and qualitative analysis of the target [16], thus providing clearer images and facilitating functional analysis [17]. Yue (2017) studied the relationship between three-dimensional reconstruction and fluid mechanics with the formation and progression of atherosclerotic plates [18].…”
Section: Discussionmentioning
confidence: 99%
“…The size of these grafts depends on the position of neurovascular bundle present at or near the donor site 1 . The possibility of haemorrhagic complication limits clinicians from harvesting the optimum sized grafts required for the treatment demands 3 .…”
Section: Introductionmentioning
confidence: 99%
“…Numerous cadaver and radiological studies have recommended safe distances from the adjacent teeth to greater palatine foramen to guide the clinicians to determine the surgical --------------------------------------------------------------------------------------Received on 19-09-2022 Accepted on 13-02-2023 borders of palatal donor sites while graft harvesting 3 . Few studies evaluate the position and topography of the neurovascular bundle by soft tissue dissection of cadavers 2 .…”
Section: Introductionmentioning
confidence: 99%